English
Language : 

A11AP-GA Datasheet, PDF (1/7 Pages) Nihon Kaiheiki Industry Co. Ltd. – General Specifications
Series A
Process Sealed Subminiature Toggles
A
General Specifications
Electrical Capacity (Resistive Load)
Logic Level: 0.4VA maximum @ 28V AC/DC maximum
(Applicable Range 0.1mA ~ 0.1A @ 20mV ~ 28V)
Note: Find additional explanation of operating range in Supplement section.
Other Ratings
Contact Resistance: 50 milliohms maximum
Insulation Resistance: 500 megohms minimum @ 500V DC
Dielectric Strength: 500V AC minimum between contacts for 1 minute minimum;
500V AC minimum between contacts & case for 1 minute minimum
Mechanical Life: 100,000 operations minimum for On-None-On & On-Off-On
50,000 operations minimum for other circuits
Electrical Life: 50,000 operations minimum
Nominal Operating Force: 1.47N (momentary); 1.18N (maintained) for .394” (10.0mm) toggles
2.73N (momentary); 1.84N (maintained) for all other toggles
Contact Timing: Nonshorting (break-before-make)
Angle of Throw: 26°
Materials & Finishes
Toggle:
Case Housing:
Support Bracket:
Movable Contact:
Stationary Contacts:
Terminals:
Glass fiber reinforced polyamide for antistatic; nickel plated brass for all others
Glass fiber reinforced polyamide
Tin plated phosphor bronze
Phosphor bronze with gold plating
Brass with gold plating
Brass with gold plating
Environmental Data
Operating Temperature Range:
Humidity:
Vibration:
Shock:
–30°C through +85°C (–22°F through +185°F)
90 ~ 95% humidity for 240 hours @ 40°C (104°F)
10 ~ 55Hz with peak-to-peak amplitude of 1.5mm traversing the frequency range
& returning in 1 minute; 3 right angled directions for 2 hours
50G (490m/s2) acceleration (tested in 6 right angled directions, with 5 shocks in each direction)
PCB Processing
Soldering:
Cleaning:
Wave Soldering Recommended. See Profile A in Supplement section.
Manual Soldering: See Profile B in Supplement section.
Automated cleaning. See Cleaning Specifications in Supplement section.
Standards & Certifications
The A Series toggles have not been tested for UL recognition or CSA certification.
These switches are designed for use in a low-voltage, low-current, logic-level circuit.
When used as intended in a logic-level circuit, the results do not produce hazardous energy.
A4
w w w.nkks w it ches.com