English
Language : 

FSF10A20B Datasheet, PDF (1/4 Pages) Nihon Inter Electronics Corporation – FRD - Low Forward Voltage Drop
ç
FRD Type : FSF10A20B
FEATURES
* Fully Molded Isolation Case
* Ultra – Fast Recovery
* Low Forward Voltage Drop
* Low Power Loss, High Efficiency
* High Surge Capability
* 200 Volts thru 600 Volts Types Available
OUTLINE DRAWING
Maximum Ratings
ç
Approx Net Weight:1.75g
Rating
Repetitive Peak Reverse Voltage
Non-repetitive Peak Reverse Voltage
Average Rectified Output Current
RMS Forward Current
Surge Forward Current
Operating JunctionTemperature Range
Storage Temperature Range
Mounting torque
Symbol
VRRM
VRSM
IO
IF(RMS)
IFSM
Tjw
Tstg
FSF10A20B
200
220
10
Tc=100°C
50 Hz Half Sine
Resistive Load
Wave
15.7
120
50 Hz Half Sine Wave,1cycle
Non-repetitive
- 40 to + 150
- 40 to + 150
0.5 Recommended value
Unit
V
A
A
A
°C
°C
N•m
Electrical • Thermal Characteristics
Characteristics
Peak Reverse Current
Peak Forward Voltage
Reverse Recovery Time
Thermal Resistance
Symbol
Conditions
IRM Tj= 25°C, VRM= VRRM
VFM Tj= 25°C, IFM= 10A
trr
IFM= 10A,
-di/dt= 50 A/µs, Ta= 25°C
Rth(j-c) Junction to Case
Rth(c-f) Case to Fin
Min.
-
-
Typ.
-
-
Max.
25
1.03
Unit
µA
V
-
-
35 ns
-
-
-
-
4
1.5
°C/W
ç