Features
• Optical Output Power: CW120mW
• Peak Wavelength: 390-400nm
• Can Type:5.6 Floating Mounted with Photo Diode and Zener Diode

Absolute Maximum Ratings

Item
Symbol
Absolute Maximum
Ratings
Unit
Optical Output Power
Po
140
mW
Allowable Reverse Current
Ir (LD)
85
mA
PD Reverse Voltage
Vr (PD)
5
V
Storage Temperature
Tstg
-40 ~ 85
C
Operating Case Temperature
Tc
-10 ~ 30
C
Outline Dimension
Unit (mm)
(90°)
Emitting Point
(0.4)
1.0±0.1
Z+
Φ 4.2±0.2
Φ 3.55±0.1
Emitting Point
Reference Plane
4×Φ 0.43±0.08
Initial Electrical/Optical Characteristics
(Tc=25C)
Item
Condition Symbol Min Typ. Max Unit
Optical Output Power
CW
Po
-
- 120 mW
Peak Wavelength
Po=120mW p 390 - 400 nm
Threshold Current
CW
Ith
-
28 50 mA
3
X+
1
2
4
Φ 2.0±0.2
Y+
( ) are reference figures
Operating Current
Po=120mW Iop
- 100 150 mA Pin Connection
Slope Efficiency
CW

1.3 1.7 2.1 W/A
Operating Voltage
Po=120mW Vop
- 4.5 5.5 V
Beam
Divergence*
Parallel
Perpendicular
Po=120mW
//

7.0
13.0
-
-
12.0
28.0


Beam Pointing Parallel
Accuracy Perpendicular
Po=120mW
//

-2.0
-2.5
-
-
Monitor Current**
Po=120mW Im
-
-
* Full angle at 50% from peak intensity
2.0 
2.5 
1.0 mA
This model has a Zener Diode built in
as a protection circuit against static
electricity.
** Monitor Current is short time power reference purpose only. Not guaranteed for accuracy.
All figures in this specification are measured by Nichia's method and may contain measurement deviations.
This model is Engineering Sample for evaluation or design purpose only. Life time is not guaranteed.
The above specifications are for reference purpose only and subjected to change without prior notice.
Safety of Laser light
 Laser Light can damage the human eyes and skin. Do not expose the eye or skin to any
laser light directly and/or through optical lens. When handling the LDs, wear appropriate
safety glasses to prevent laser light, even any reflections from entering to the eye. Focused
laser beam through optical instruments will increase the chance of eye hazard.
 These LDs are classified in Class 4 of IEC60825-1 and 21 CFR Part 1040.10 Safety
Standards. It is absolutely necessary to take overall safety measures against User's
modules, equipment and systems into which Nichia LDs are incorporated and/or integrated.
NICHIA CORPORATION
http://www.nichia.co.jp
 HEADQUARTERS
491 Oka, Kaminaka-Cho, Anan-Shi, TOKUSHIMA 774-8601, JAPAN
PHONE: +81-884-22-2311 FAX: +81-884-21-0148
 CONTACT
TOKYO SALES OFFICE
13F Tamachi Center Building
PHONE: +81-3-3456-3108
34-F7A, XS:h+ib8a1-53--C5h4o4m0-e7,3M30inato-Ku,
TOKYO
108-0014,
JAPAN
-1-