Blue Laser Diode for External Cavity
NDBA116T
Test Sample
Features
• For External Cavity Laser with Low Reflection Coating on front facet
• Optical Output Power: 30mW (Pulse)
• Can Type: 5.6 mm Floating Mounted with Photo Diode and Zener Diode
Absolute Maximum Ratings
(Pulse *1)
Outline Dimension
Unit (mm)
Item
Symbol
Absolute Maximum
Ratings
Unit
Optical Output Power
Po
45
mW
LD Forward Current
If
280
mA
Allowable Reverse Current
Ir (LD)
85
mA
PD Reverse Voltage
Vr (PD)
20
V
Storage Temperature
Tstg
-25 ~ 75
C
Operating Case Temperature
Tc
10 ~ 30
C
*Pulse Condition: Pulse Width 2.5μs, Duty 5%
Initial Electrical/Optical Characteristics
(Pulse*1 Ta=23C *2)
Item
Condition Symbol Min Typ. Max Unit
Optical Output Power
Pulse
Po
-
-
30 mW
Peak Wavelength
Po=30mW
p
450
-
455 nm
Threshold Current
Pulse
Ith
-
210
-
mA
Operating Current Po=30mW Iop
-
230
-
mA
Slope Efficiency
Pulse

-
1.5
- W/A
( ) are reference figures
Operating Voltage Po=30mW Vop
-
7.1
-
V
Pin Connection
Beam Divergence*3 Po=30mW
//

7
15
-
12 deg.
-
25 deg.
Emission
Point
Angle Po=30mW
//
Accuracy

-2.0
-3.0
-
-
2.0 deg.
3.0 deg.
Monitor Current*4 Po=30mW
Im
-
-
1
mA
*1 The Laser can NOT be lasing under CW operating without External Cavity. Pulse 0.5μs,
Duty 20%
*2 There is some range in ambient temperature. *3 Full angle at 50% from peak intensity.
*4 Monitor Current is short time power reference purpose only. Not guaranteed for
accuracy. This value must be affected intensely by feedback from composing optics.
This model has a zener diode built in
as protection circuit against static
electricity.
All figures in this specification are measured by Nichia's method and may contain measurement deviations.
Diffractive feedback efficiency to the Laser diode must be limited less than 30 % under the External cavity configuration.
This model can only be performed under CW operating with External Cavity.
This model is Test Sample for evaluation or design purpose only. Life time is not guaranteed.
The above specifications are for reference purpose only and subjected to change without prior notice.
Safety of Laser light
 Laser Light can damege the human eyes and skin. Do not expose the eye or skin to any
laser light directly and/or through optical lens. When handling the LDs, wear appropriate
safety glasses to prevent laser light, even any reflections from entering to the eye. Focused
laser beam through optical instruments will increase the chance of eye hazard.
 These LDs are classified in Class 4 of IEC60825-1 and 21 CFR Part 1040.10 Safety
Standards. It is absolutely necessary to take overall safety measures against User's
modules, equipment and systems into which Nichia LDs are incorporated and/or integrated.
NICHIA CORPORATION
http://www.nichia.co.jp
 HEADQUARTERS
491 Oka, Kaminaka-Cho, Anan-Shi, TOKUSHIMA 774-8601, JAPAN
PHONE: +81-884-22-2311 FAX: +81-884-21-0148
 CONTACT
TOKYO SALES OFFICE
13F Tamachi Center Building
PHONE: +81-3-3456-3108
34-F7A, XS:h+ib8a1-53--C5h4o4m0-e7,3M30inato-Ku,
TOKYO
108-0014,
JAPAN
-1-