English
Language : 

NDB4216E-E Datasheet, PDF (1/3 Pages) NICHIA CORPORATION – Blue Laser Diode
[ UTZ-SC0319_2 ]
2012/10/02
Blue Laser Diode
NDB4216E

Features
• Optical Output Power: CW 100mW
• Can Type: 5.6 mm Floating Mounted with Photo Diode and Zener Diode
Engineering Sample
Outline Dimension
Unit (mm)
Absolute Maximum Ratings
Item
Optical Output Power
Allowable Reverse Current
PD Reverse Voltage
Storage Temperature
Operating Case Temperature
Symbol
Absolute
Maximum Ratings
Unit
Po
120
mW
Ir (LD)
85
mA
Vr (PD)
5
V
Tstg
-40 ~ 85
C
Tc
-10 ~ 60
C
(90°)
Emitting Point
(0.4)
1.0±0.1
Z+
Φ 4.2±0.2
Φ 3.55±0.1
Emitting Point
Reference Plane
Initial Electrical/Optical Characteristics
(Tc=25C)
Item
Condition Symbol Min Typ. Max Unit
Optical Output Power
CW
Po
-
- 100 mW
4×Φ 0.43±0.08
Peak Wavelength
Po=100mW p
450 - 460 nm
3
Threshold Current
Operating Current
Slope Efficiency
Operating Voltage
CW
Ith
Po=100mW Iop
CW

Po=100mW Vop
15 30 55 mA
X+
1
2
80 110 150 mA
0.7 1.2 1.7 W/A
4
Φ 2.0±0.2
(Y+) are reference figures
4.0 5.2 6.5 V Pin Connection
Beam
Divergence*
Parallel
Perpendicular
Po=100mW
Beam
Parallel
Pointing
Po=100mW
Accuracy Perpendicular
Monitor Current**
Po=100mW
//

//

Im
6.0 8.5 12.5 °
17.0 23.0 27.0 °
-2.5 - 2.5 °
-3.0 - 3.0 °
0.2 1.0 2.0 mA
* Full angle at 50% from peak intensity
This model has a Zener Diode built in
** Monitor Current is short time power reference purpose only. Not guaranteed for
accuracy.
as a protection circuit against static
electricity.
All figures in this specification are measured by Nichia's method and may contain measurement deviations.
This model is Engineering Sample for evaluation or design purpose only. Life time is not guaranteed.
The above specifications are for reference purpose only and subjected to change without prior notice.
Safety of Laser light
 Laser Light can damage the human eyes and skin. Do not expose the eye or skin to any
laser light directly and/or through optical lens. When handling the LDs, wear appropriate
safety glasses to prevent laser light, even any reflections from entering to the eye. Focused
laser beam through optical instruments will increase the chance of eye hazard.
 These LDs are classified in Class 4 of IEC60825-1 and 21 CFR Part 1040.10 Safety
Standards. It is absolutely necessary to take overall safety measures against User's
modules, equipment and systems into which Nichia LDs are incorporated and/or integrated.
NICHIA CORPORATION
http://www.nichia.co.jp
 HEADQUARTERS
491 Oka, Kaminaka-Cho, Anan-Shi, TOKUSHIMA 774-8601, JAPAN
PHONE: +81-884-22-2311 FAX: +81-884-21-0148
 CONTACT
TOKYO SALES OFFICE
13F Tamachi Center Building
PHONE: +81-3-3456-3108
34-F7A, XS:h+ib8a1-53--C5h4o4m0-e7,3M30inato-Ku,
TOKYO
108-0014,
JAPAN
-1-