English
Language : 

NDB4116 Datasheet, PDF (1/3 Pages) NICHIA CORPORATION – Blue Laser Diode
Blue Laser Diode
NDB4116
[ UTZ-SC0284_5 ]
2012/10/02
Features
• Optical Output Power: CW 100mW
• Can Type: φ 5.6 mm Floating Mounted with Photo Diode and Zener Diode
Outline Dimension
Unit (mm)
Absolute Maximum Ratings
Item
Optical Output Power
Allowable Reverse Current
PD Reverse Voltage
Storage Temperature
Operating Case Temperature
Symbol
Absolute
Maximum Ratings
Unit
Po
120
mW
Ir (LD)
85
mA
Vr (PD)
5
V
Tstg
-40 ~ 85
°C
Tc
-10 ~ 60
°C
(90°)
Emitting Point
(0.4)
1.0±0.1
Z+
Φ 4.2±0.2
Φ 3.55±0.1
Emitting Point
Reference Plane
Initial Electrical/Optical Characteristics
(Tc=25°C)
4×Φ 0.43±0.08
Item
Condition Symbol Min Typ. Max Unit
3
Optical Output Power
CW
Po
-
- 100 mW
X+
Peak Wavelength
Po=100mW λp
440 445 450 nm
1
2
4
Threshold Current
CW
Ith
10 25 50 mA
Φ 2.0±0.2
Y+
Operating Current
Po=100mW Iop
80 100 140 mA
( ) are reference figures
Slope Efficiency
CW
η
0.8 1.3 1.8 W/A Pin Connection
Operating Voltage
Po=100mW Vop 4.5 5.3 6.0 V
Beam
Parallel Po=100mW θ//
7.0 8.5 12.5 °
Divergence* Perpendicular Po=100mW θ⊥
17.0 23.5 25.0 °
Beam
Parallel Po=100mW ∆θ// -2.5 - 2.5 °
Pointing
Accuracy Perpendicular Po=100mW ∆θ⊥
-3.0 -
3.0
°
Monitor Current**
Po=100mW Im
0.2 1.0 2.0 mA
This model has a Zener Diode built in
* Full angle at 50% from peak intensity
** Monitor Current is short time power reference purpose only. Not guaranteed for
as a protection circuit against static
electricity.
accuracy.
All figures in this specification are measured by Nichia's method and may contain measurement deviations.
The above specifications are for reference purpose only and subjected to change without prior notice.
Safety of Laser light
Laser Light can damege the human eyes and skin. Do not expose the eye or skin to any
laser light directly and/or through optical lens. When handling the LDs, wear appropriate
safety glasses to prevent laser light, even any reflections from entering to the eye. Focused
laser beam through optical instruments will increase the chance of eye hazard.
These LDs are classified in Class 4 of IEC60825-1 and 21 CFR Part 1040.10 Safety
Standards. It is absolutely necessary to take overall safety measures against User's
modules, equipment and systems into which Nichia LDs are incorporated and/or integrated.
NICHIA CORPORATION
http://www.nichia.co.jp
HEADQUARTERS
491 Oka, Kaminaka-Cho, Anan-Shi, TOKUSHIMA 774-8601, JAPAN
PHONE: +81-884-22-2311 FAX: +81-884-21-0148
CONTACT
TOKYO SALES OFFICE
13F Tamachi Center Building 34-7, Shiba 5-Chome, Minato-Ku, TOKYO 108-0014, JAPAN
PHONE: +81-3-3456-3108 FAX: +81-3-5440-7330
-1-