PXI-5671 Datasheet, PDF (4/5 Pages) National Instruments Corporation – 250 kHz to 2.7 GHz/16-bit resolution, 100 MS/s arbitrary waveform generation
2.7 GHz RF Vector Signal Generator
Output 1 dB Gain Compression Point (minimum)
Output Frequency (GHz)
Up to 2.0
2.0 to 2.5
2.5 to 2.7
15 to 35 °C (dBm)
16
14
13
0 to 55 °C (dBm)
14.5
12.5
11.5
Noise density (0 dBm output)
Output Power Level (dBm)
0
-20
Typical Noise Floor at 2 GHz
15 to 35 °C (dBm/Hz)
-120
-140
0 to 55 °C (dBmHz)
-115
-135
Output Power Level (dBm)
-57
-50
-40
-30
-20
-10
0
10
Typical Noise Floor (dBm/Hz)
-158
-157
-154
-147
-140
-130
-120
-110
Vector modulation bandwidth flatness............ ±0.5 dB typical1
Group delay variation (within the vector
modulation bandwidth) ............................. ±20 ns typical
Group delay
PXI-5441..................................................... 750 ns typical
PXI-5610..................................................... 1200 ns typical
Overload protection on RF output
Maximum reverse RF power ..................... 4 W
Maximum DC input.................................... ±50 VDC
1Equilization enabled. ±1.8 dB maximum with equilization disabled.
Local Oscillator Output
Frequency range ............................................... 3.2 to 5.9 GHz
Output power ................................................... -22 dBm (typical)
VSWR ............................................................... 1.5:1 maximum
Phase noise – Local Oscillator
Offset Frequency (kHz)
1
10
100
3.2 GHz (dBc/Hz)
-89
-98
-120
Carrier Frequency
4.2 GHz (dBc/Hz)
-88
-98
-120
5.2 GHz (dBc/Hz)
-85
-95
-120
FM Modulation
FM Distortion (modulation
frequency 1 kHz, carrier frequency
1 GHz, FM deviation 100 kHz,
filter bandwidth 2 MHz .................................... <1% Typical
Digital Modulation
QPSK, 16-QAM, 64-QAM (root raised cosine Filter, alpha = 0.25,
carrier frequency = 1 GHz, 2,000 symbol PRBS, equalization: ON)
Symbol Rate
EVM (%)
200 kS/s
1.0
1 MS/s
1.0
2.56 MS/s
1.0
5.12 MS/s
1.0
10 MS/s
1.2
Power Requirements
Typical
PXI-5610
PXI-5441
+3.3 VDC
150 mA
150 mA
+5 VDC
2.6 A
2.6 A
+12 VDC
900 mA
900 mA
MER (dB)
37.0
37.0
37.0
37.0
36.0
-12 VDC
60 mA
60 mA
Total Power
25.0 W
25.0 W
Calibration
Self-calibration
PXI-5610..................................................... Correction for YIG offset and gain
PXI-5441..................................................... Correction for DC gain offset and timing errors
External calibration interval
PXI-5610..................................................... 1 year
PXI-5441..................................................... 2 years
Physical
PXI-5610 (2 slots) ............................................. 10 by 16 cm (3.9 by 6.3 in.)
PXI-5441 (1 slot) ............................................... 10 by 16 cm (3.9 by 6.3 in.)
Environmental
Operating Environment
Operating temperature .............................. 0 to +55 °C
(Tested in accordance with IEC-60068-2-1 and IEC-60068-2-2)1
Relative humidity....................................... 10 to 90%, noncondensing
(Tested in accordance with IEC 60068-2-56)
Altitude (indoor use only) ......................... 0 to 2,000 m (at 25 °C ambient temperature)
Storage Environment
Ambient temperature ................................ -20 to 70 °C
(Tested in accordance with IEC-60068-2-1 and IEC-60068-2-2.)
Relative humidity....................................... 5 to 95%, noncondensing
(Tested in accordance with IEC-60068-2-56.)
Shock and Vibration
Nonoperational shock ............................... 30 g peak, half-sine, 11 ms pulse
(Tested in accordance with IEC-60068-2-27. Test profile
developed in accordance with MIL-PRF-28800F.)
Random vibration Non-operating.............. 5 to 500 Hz, 2.4 grms
(Tested in accordance with IEC-60068-2-64. Non-operating
test profile exceeds the requirements of MIL-PRF-2880F,
Class B)
1When installed in the NI PXI-101x or PXI-1000B chassis, the PXI-5441 operating temperature is 0 to +45 °C
Certifications and Compliances
CE Mark Compliance
Safety
This product is designed to meet the requirements of the following standards of safety for electrical
equipment for measurement, control, and laboratory use:
• IEC 61010-1, EN 61010-1
• UL 61010-1
• CAN/CSA C22.2 No. 61010-1
Electromagnetic Compatibility
Emissions................................................... EN 55011 Class A at 10 m FCC Part 15A above 1 GHz
Immunity .................................................... EN 61326:1997 + A2:2001, Table 1
EMC/EMI ................................................... CE, C-Tick and FCC Part 15 (Class A) Compliant
Ordering Information
NI PXI-5671
32 MB memory ........................................................779079-02
256 MB memory ......................................................779079-03
512 MB memory ......................................................779079-04
Includes PXI-5610, PXI-5441, NI-RFSG, Modulation Toolkit for LabVIEW,
and cables.
BUY NOW!
For complete product specifications, pricing, and accessory
information, call (800) 813-3693 (U.S. only) or go to ni.com/rf.
4 National Instruments • Tel: (800) 813 3693 • info@ni.com • ni.com