English
Language : 

PXI-PCIE8361 Datasheet, PDF (3/4 Pages) National Instruments Corporation – PCI Express Control of PXI (MXI-Express)
PCI Express Control of PXI (MXI-Express)
Specifications
Specifications are subject to change without notice.
Bus Interface
Form factor............................................. x1 PCI Express
Slot compatibility................................... x1, x4, x8, and x161
PCI Express slots
1Some motherboard manufacturers intend the x16 slot for graphics use and preinstall a graphics board.
Check with the motherboard manufacturer for alternative graphics solutions if using the x16 slot for a
nongraphics board.
Power Requirements
NI PXI-8360
NI PCIe-8361
NI PCIe-8362
Power Rail
+3.3 V
+5 V
+12 V
-12 V
+3.3 V
+3.3 VAUX
+12 V
+3.3 V
+3.3 VAUX
+12 V
Typical Current
1.500 A
5 mA
5 mA
0 mA
1.800 A
0A
0A
580 mA
10 mA
0A
Maximum Current
1.750 A
20 mA
20 mA
0 mA
2.000 A
0A
0A
1.040 A
50 mA
0A
Physical
Dimensions
NI PXI-8360.......................................
NI PCIe-8361.....................................
NI PCIe-8362.....................................
Slot requirements
NI PXI-8360.......................................
NI PCIe-8361 and PCIe-8362.............
Maximum cable length..........................
Compatibility..........................................
10.0 by 16.0 cm (3.9 by 6.3 in.)
10.7 by 17.5 cm (4.4 by 6.9 in.)
9.93 by 7.11 cm (3.91 by 2.8 in.)
One 3U PXI system controller slot
One PCI Express slot
7m
Fully compatible with the PXI Hardware
Specification, Revision 2.1, and the
PCI Express Specification, Revision 1.0a
Operating Environment
NI PXI-8360, PCIe-8361, PCIe-8362
Ambient temperature range..............
Relative humidity range....................
0 to 55 °C
(tested in accordance with
IEC-60068-2-1 and IEC-60068-2-2;
meets MIL-PRF-28800F Class 3 low
temperature limit and MIL-PRF-28800F
Class 2 high temperature limit)
10 to 90%, noncondensing
(tested in accordance with IEC-60068-2-56)
Maximum altitude................................. 2,000 m
Pollution Degree.................................... 2
Indoor use only.
Storage Environment
NI PXI-8360
Ambient temperature range..............
Relative humidity range....................
NI PCIe-8361
Ambient temperature range..............
Relative humidity range....................
NI PCIe-8362
Ambient temperature range..............
Relative humidity range....................
-20 to 70 °C
(tested in accordance with
IEC-60068-2-1 and IEC-60068-2-2;
meets MIL-PRF-28800F Class 3 limits)
5 to 95%, noncondensing
(tested in accordance
with IEC-60068-2-56)
-20 to 70 °C
(tested in accordance with
IEC-60068-2-1 and IEC-60068-2-2)
5 to 95%, noncondensing
(tested in accordance
with IEC-60068-2-56)
-40 to 70 °C
(tested in accordance with
IEC-60068-2-1 and IEC-60068-2-2)
5 to 95%, noncondensing
(tested in accordance
with IEC-60068-2-56)
Shock and Vibration
NI PXI-8360
Operating............................................... 30 g peak, half-sine, 11 ms pulse
(tested in accordance with
IEC-60068-2-27; test profile developed
in accordance with MIL-PRF-28800F)
Random Vibration
Operating...........................................
Nonoperating....................................
5 to 500 Hz, 0.3 grms
5 to 500 Hz, 2.4 grms
(tested in accordance with
IEC-60068-2-64; nonoperating test
profile exceeds the requirements of
MIL-PRF-28800F, Class 3)
Note: For full EMC compliance, operate this device with shielded cabling. In addition, all covers
and filler panels must be installed. Refer to the Declaration of Conformity (DoC) for this product
for any additional regulatory compliance information. To obtain the DoC for this product, visit
ni.com/certification, search by model number or product line, and click the appropriate link in
the Certification column.
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
3