English
Language : 

PXI-8104RT Datasheet, PDF (3/5 Pages) National Instruments Corporation – 1.86 GHz Intel Celeron M Real-Time Embedded Controllers for PXI
1.86 GHz Intel Celeron M Real-Time Embedded Controllers for PXI
Specifications subject to change without notice.
Features
Processor.............................................
Chipset ................................................
Front-side bus .....................................
System memory (RAM) .......................
Ethernet...............................................
Hard drive............................................
Video ...................................................
Serial ...................................................
Parallel ...............................................I
Hi-Speed USB .....................................
Intel 1.86 GHz Celeron M 440
Mobile Intel 945GME
Express chipset
533 MHz
512 MB dual-channel DDR2
RAM PC2 5300 (standard)
2 GB dual-channel DDR2 RAM
PC2 5300 (maximum)
10/100/1000BASE-TX,
RJ45 connector
60 GB minimum, internal 2.5 in.,
9.5 mm Serial ATA 1.0 interface
Intel Extreme Graphics controller
1 (RS232)
IEEE 1284 Type C miniature
connector (adapter cable
not included)
4
Voltage (V)
+3.3
+5
+12
-12
Ty p i c a l
2.5 A
3.5 A
5 mA
0.0 A
C u rre n t
Maximum
3.25 A
5.5 A
5 mA
0.0 A
Power Requirements
Physical
Board dimensions ...............................
Slot requirements ...............................
Compatibility .......................................
Weight.................................................
4-wide 3U PXI Express module
1 system slot plus 3 controller
expansion slots
Fully compatible with
PXI specification
0.94 kg (2.1 lb) typical
Environment
Maximum altitude...............................
Pollution degree ..................................
Indoor use only
2,000 m (800 mbar) at 25 °C
ambient temperature
2
Operating Environment
Ambient temperature range ...............
Relative humidity range......................
5 to 50 °C in an NI PXI-1042
chassis (tested in accordance
with IEC-60068-2-1 and
IEC-60068-2-2)
10 to 90%, noncondensing
(tested in accordance with
IEC-60068-2-56)
Storage Environment
Ambient temperature range ...............
Relative humidity range......................
-40 to 65 °C (tested in
accordance with IEC-60068-2-1
and IEC-60068-2-2)
5 to 95% noncondensing
(tested in accordance with
IEC-60068-2-56)
Shock and Vibration
Operating shock ..................................
Random vibration
Operating ........................................
Nonoperating ..................................
30 g peak, half-sine, 11 ms pulse
(tested in accordance with
IEC-60068-2-27; test profile
developed in accordance
with MIL-PRF-28800F)
5 to 500 Hz, 0.3 grms
(with solid-state hard drive)
5 to 500 Hz, 2.4 grms
(tested in accordance with
IEC-60068-2-64; nonoperating
test profile exceeds the
requirements of MIL-PRF-28800F,
Class 3)
Safety and Compliance
Safety
This product is designed to meet the requirements of the following
standards of safety for electrical equipment for measurement, control,
and laboratory use:
• IEC 61010-1, EN 61010-1
• UL 61010-1, CSA 61010-1
Note: For UL and other safety certifications, refer to the product label or
visit ni.com/certification, search by model number or product line, and
click the appropriate link in the Certification column.
Electromagnetic Compatibility
This product is designed to meet the requirements of the following
standards of EMC for electrical equipment for measurement, control,
and laboratory use:
• EN 61326 EMC requirements; Minimum Immunity
• EN 55011 Emissions; Group 1, Class A
• CE, C-Tick, ICES, and FCC Part 15 Emissions; Class A
Note: For EMC compliance, operate this device according to
product documentation.
CE Compliance
This product meets the essential requirements of applicable European
Directives, as amended for CE marking, as follows:
• 2006/95/EC; Low-Voltage Directive (safety)
• 2004/108/EC; Electromagnetic Compatibility Directive (EMC)
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)