English
Language : 

PDMB300BS12_15 Datasheet, PDF (3/4 Pages) National Instruments Corporation – IGBT
PDMB300BS12
PDMB300BS12C
QS043-402-20372(4/5)
Fig.7- Collector Current vs. Switching Time (Typical)
2
VCC=600V
RG=5.1(
VGE=±15V
1.6
TC=25°C
Resistive Load
tOFF
1.2
0.8 tf
0.4
0
0
tON
tr(VCE)
50
100
150
200
250
300
Collector Current IC (A)
Fig.9- Collector Current vs. Switching Time
10
3
tOFF
1
tf
0.3
tON
VCC=600V
RG=5.1(
VGE=±15V
TC=125°C
Inductive Load
0.1
tr(Ic)
0.03
0.01
0
50
100
150
200
250
300
350
Collector Current IC (A)
Fig.11- Collector Current vs. Switching Loss
120
VCC=600V
RG=5.1(
100 VGE=±15V
TC=125°C
Inductive Load
80
EON
60
EOFF
40
ERR
20
0
0
100
200
300
400
500
Collector Current IC (A)
Fig.8- Series Gate Impedance vs. Switching Time (Typical)
5
VCC=600V
3 IC=300A
VGE=±15V
TC=25°C
Resistive Load
1
toff
tf
0.3 ton
0.1 tr(VCE)
0.03
3
10
30
Series Gate Impedance RG (()
Fig.10- Series Gate Impedance vs. Switching Time
10
VCC=600V
5 IC=300A
VGE=±15V
TC=125°C
2 Inductive Load
1 toff
0.5 ton
0.2
tf
0.1
tr(IC)
0.05
0.02
3
10
30
50
Series Gate Impedance RG (()
Fig.12- Series Gate Impedance vs. Switching Loss
300
VCC=600V
IC=300A
VGE=±15V
TC=125°C
Inductive Load
100
EON
EOFF
30
ERR
10
3
10
30
Series Gate Impedance RG (()
01
日本インター株式会社