High-Density Electromechanical Relay Multiplexers
Specifications
Specifications subject to change without notice. Visit ni.com/manuals for
the latest full specifications.
Input Characteristics
Maximum switching voltage
Channel-to-ground ............................
Channel-to-channel ..........................
Maximum switching/carry current ...
Maximum switching power
AC systems .......................................
Typical DC path resistance
Initial .................................................
End of life..........................................
Thermal EMF.....................................
Bandwidth (-3 dB)
1-wire................................................
2-wire................................................
300 V, CAT I
300 V
2A
60 W, 62.5 VA
(per channel, resistive)
<0.5 Ω
≥1 Ω
<12 μV
>9 MHz
>8 MHz
Dynamic Characteristics
Maximum speed.................................... 140 cycles/s
Relay operate time
Typical............................................... 1 ms
Maximum.......................................... 3.4 ms
Expected relay life
Mechanical ....................................... 1x108 cycles
Electrical
10 VDC, 100 mADC, resistive ............... 2.5x106 cycles
10 VDC, 1 ADC, resistive ...................... 1x106 cycles
30 VDC, 1 ADC, resistive ....................... 5x105 cycles
60 VDC, 1 ADC, resistive ....................... 1x105 cycles
Physical
Relay types............................................
Contact material....................................
I/O connectors.......................................
Dimensions............................................
Electromechanical, latching
Palladium-ruthenium, gold-covered
200 POS LFH Matrix 50, receptacle
10 by 17.4 cm (3.9 by 6.9 in.)
single-slot, 3U
Environment
Operating temperature..........................
Storage temperature.............................
Relative humidity ..................................
Pollution degree ....................................
Indoor use only.
0 to 55 °C
-20 to 70 °C
5 to 85% noncondensing
2
Safety Compliance
◾ IEC 61010-1, EN 61010-1
◾ UL 61010-01, CSA 61010-1
Electromagnetic Compatibility
This product meets the requirements of the following EMC standards for
electrical equipment for measurement, control, and laboratory use:
◾ EN 61326 (IEC 61326): Class A emissions; Basic immunity
◾ EN 55011 (CISPR 11): Group 1, Class A emissions
◾ AS/NZS CISPR 11: Group 1, Class A emissions
◾ FCC 47 CFR Part 15B: Class A emissions
◾ ICES-001: Class A emissions
Note: For EMC compliance, operate this product according to the documentation.
CE Compliance
This product meets the essential requirements of applicable European Directives
as follows:
◾ 2006/95/EC; Low-Voltage Directive (safety)
◾ 2004/108/EC; Electromagnetic Compatibility Directive (EMC)
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
2