English
Language : 

PXI-2576 Datasheet, PDF (1/4 Pages) National Instruments Corporation – 16 4x1 (2-wire), octal 8x1 (2-wire),quad 16x1 (2-wire), dual 32x1 (2-wire),64x1 (2-wire)
64-Channel Multibank Multiplexer
NI PXI-2576 NEW!
• 16 4x1 (2-wire), octal 8x1 (2-wire),
quad 16x1 (2-wire), dual 32x1 (2-wire),
64x1 (2-wire)
• Up to 100 VDC/100 VAC
• Up to 1 A switching
• Up to 30 W, 37.5 VA
• Full software programmability
• Onboard relay count tracking for
predictive maintenance
• 145 channels/s
Operating Systems
• Windows 2000/NT/XP
• Linux®
Recommended Software
• NI Switch Executive
• LabVIEW
• LabVIEW Real-Time Module
• LabWindows/CVI
• Measurement Studio
Other Compatible Software
• Visual Basic
• C/C++
Driver/Services Software (included)
• NI-SWITCH
• NI-DAQmx
Overview
Software
The National Instruments PXI-2576 is a multibank multiplexing module
with 16 banks of 4x1 2-wire multiplexers. With the flexible architecture
of the NI PXI-2576, you can configure it in a variety of topologies
that make it suitable for parallel measurement operations requiring
low-channel counts. In addition, you can combine all multiplexers on
the PXI-2576 to form a single high-channel-count multiplexer featuring
64 2-wire channels. The module can be programmed with a variety of
software including NI-SWITCH and NI Switch Executive.
All National Instruments PXI switch modules are shipped with
NI-SWITCH, an IVI-compliant driver offering complete functionality
for all switch modules. For additional assistance in configuring,
programming, and managing higher-channel-count switching systems,
NI Switch Executive software offers an easy-to-use, intelligent switch
management and visual routing environment. Use the NI-SWITCH
Soft Front Panel for simple relay operations or debugging
switch code/execution.
Automatic Scanning
The PXI-2576 maximizes throughput in automated test applications
using scanning. Scanning improves throughput by downloading a list
of up to 32,000 connections to the switch and cycling through the list
using an event (trigger) without any interruption from the host processor.
Scanning is most efficiently accomplished by mating the PXI-2576 with
an
instrument,
such
as
the
NI
PXI-4070
6
⁄1
2
-digit
FlexDMM,
which
issues
a trigger after each measurement.
Relay Count Tracking
The PXI-2576 counts relay closures on each relay. Relay counts are
incremented each time a relay is actuated. You can retrieve the
counts, stored on board the module, programmatically and use them
for predictive maintenance to reduce unexpected system downtime.
Ordering Information
NI PXI-2576............................................................................778572-76
Includes NI-SWITCH and NI-DAQmx driver software.
Accessories
NI TB-2676 terminal block ....................................................779535-01
NI Switch Executive
Development System ........................................................778546-01
Deployment Engine ..........................................................778548-00
BUY NOW!
For complete product specifications, pricing, and accessory
information, call (800) 813 3693 (U.S.) or go to ni.com/switches.