RC001 Datasheet, PDF (1/2 Pages) Nel Frequency Controls,inc – Redundant Clock Module Positive ECL Compatible Differential Output | |||
|
RC001
⢠Clock Redundancy
⢠Zero Downtime
⢠HALT/HASS Veriï¬ed
⢠Up to 250.000 MHz
RC001 Redundant Clock Module
Positive ECL Compatible Differential Output
U.S. Patent 6,970,045 0314C Rev F
Description
The Redundant Clock Module is intended to supply highly reliable ï¬xed clock reference.
This clock output is based on two clock references internal that are monitored and eliminated
from use if they are not operating within tolerance. A slow transition between oscillator references
during switching is controlled to assure no signiï¬cant phase shift or runt pulses will affect the
end user application. Osc. 0 Enable or Osc. 1 Enable is used to disable respective oscillator to
verify switching functionality. The oscillator status outputs indicate if the respective oscillator is
functioning properly or not.
Features
⢠HALT/HASS veriï¬ed
⢠Frequency range: 20.000MHz to
250.000MHz
⢠User speciï¬ed tolerance from ±100ppm
⢠Cover at electrical ground
⢠Will withstand SMD reï¬ow temperatures
of 253°C for 4 minutes maximum
⢠MECL compatible outputs
⢠High shock resistance, to 1000g
⢠Leaded package
⢠Ten low skew DPECL outputs
Electrical Connection
Pin
Connection
Pin
Connection
Pin
1
Q6
17
Vcc
33
2
/Q6
18
Vcc
34
3
Vcc
19
GND
35
4
Q7
20
GND
36
5
/Q7
21
Vcc
37
6
GND
22
Vcc
38
7
Q8
23
GND
39
8
/Q8
24
GND
40
9
Vcc
25
/Osc 0 status
41
10
Q9
26
Osc 0 status
42
11
/Q9
27
/Osc 1 status
43
12
GND
28
Osc 1 status
44
13
EN1
29
Osc select
45
14
EN0
30
/Reset
46
15
GND
31
Vcc
47
16
GND
32
Q0
48
Note: Osc X status is logic low for pass and logic high for fail
Drawing Speciï¬cations
Connection
/Q0
GND
Q1
/Q1
Q2
/Q2
Vcc
Q3
/Q3
Vcc
GND
Q4
/Q4
GND
GND Q5
GND /Q5
For the most up to date
speciï¬cations on each NEL
product, log on to our
websiteâwww.nelfc.com
A1
|
▷ |