English
Language : 

UPG181GR Datasheet, PDF (3/12 Pages) NEC – GaAs MMIC DBS Twin IF Switch
µPG181GR
RECOMMENDED OPERATING CONDITIONS (TA = +25 °C)
Parameter
Control Voltage (High)
Control Voltage (Low)
Symbol
VCONT(H)
VCONT(L)
MIN.
+4.5
−0.5
TYP.
+5
0
MAX.
Unit
+5.5
V
+0.5
V
ELECTRICAL CHARACTERISTICS (TA = +25 °C, unless otherwise specified: VCONT1 to VCONT4 =
0/ +5 V, ZO = 50 Ω, LL, LR, RL, RR Each Port)
Parameter
Symbol
Test Conditions
MIN.
TYP.
MAX.
Unit
Insertion Loss
LINS
f = 0.95 GHz to 2.15 GHz
−
5.0
7.0
dB
Insertion Loss Flatness
∆LINS
| LINS (0.95 GHz) − LINS (1.7 GHz) |
−
0.5
1.2
dB
Insertion Loss Flatness
∆LINS
| LINS (0.95 GHz) − LINS (2.15 GHz) |
−
0.8
1.5
dB
Channel Isolation
ISL
f = 0.95 GHz to 1.7 GHz
30
33
−
dB
Channel Isolation
ISL
f = 1.7 GHz to 2.15 GHz
25
30
−
dB
Output Return Loss
RLout
f = 0.95 GHz to 2.15 GHz
13
16
−
dB
Control Current
ICONT
VCONT = +5 V/0 V, RF OFF
−
−
200
µA
Data Sheet P14268EJ2V0DS00
3