English
Language : 

OHD1-M Datasheet, PDF (13/27 Pages) NEC – NEC TOKIN Sensors
Output Characteristics
● CT-05, CT-07 AC output characteristics (example)
● CT-06 AC output characteristics (example)
1000
RL=100
100
10
RL=10
CT-07-100
CT-07-50 (CT-05)
CT-07-50 (CT-05)
CT-07-100
1
0.1
1
10
100
Primary Current I1 (AT)
500
CT-06-50
CT-06-75
CT-06-100
200
CT-06-50
100
70
RL=100Ω
CT-06-75
CT-06-100
50
30
20
RL=10Ω
10
7
5
0.1 0.2
0.5 0.7 1 2 3 5 7 10
Primary current I1 (AT)
● Measuring circuit
I1
RL Eo
I1 : Primary current (AT)
RL : Load resistance (Ω)
Eo : Output voltage (mV rms)
Before Using Current Transformers Low Current Type
• The core may be damaged if applied with a strong impact. Carefully avoid dropping or applying any other
strong impacts.
• Preliminary study is needed with regard to heating by current conduction.
• Do not use the current transformer opened between secondary output terminals.
In the worst case, heat build-up in the magnetic core may occur, resulting in dameges to the parts by the melting
of coil due to this heat.
NEC TOKIN Sensors Vol.11 13
●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact NEC TOKIN for updated product data.
●Please request for a specification sheet for detailed product data prior to the purchase.
●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.
2012.06.04 0000SENVOL11E1206H0