HE1AN-DC6V Datasheet, PDF (6/6 Pages) Nais(Matsushita Electric Works) – TV-15, 30 AMP (1 Form A) Power Relay
HE RELAY ACCESSORIES
Terminal socket instantly attachable to DIN rail
HE
TYPES
Part No.
JH1-SF
JH2-SF
Applicable relays
HE1a/JH1a
HE2a/JH2a
SPECIFICATIONS
Part No.
JH1, JH2
Maximum continuous
current*
20 A 250 V AC (1a: 30 A 250 V AC)
Breakdown voltage
2,000 Vrms between terminals
Insulation resistance
More than 1,000 MΩ between poles
Heat resistance
150°C ±3°C for 1 hour
* Don't insert or remove relays while in the energized condition.
DIMENSIONS
1 Form A, 2 Form A
96
.354 8
60
2.362
22
.866
97
.354 5
10.25
.404
1
2
11
.433
14.4
.567
3
11
.433
4
8.4
.331
34
4
.157
1.339
70
2.756
MOUNTING METHOD
1. Relay mounting
9.2
.362
16
.630
23
.906
Relay mounting diagram
61
2.402
mm inch
Panel cutout
40
1.575
2-DIA. 4.2
2-DIA. .165
(2-M4 Screw hole)
(2-M.157 Screw hole)
2. Installing to a DIN rain
3. Removing from a DIN rain
Push
Flat-head screw driver
NOTE
1. Be careful not to drop the relay. It is
made of heat-hardened resin and may
break.
2. Be sure to tighten the screw- down ter-
minals firmly. Loose terminals may lead to
the generation of heat.
12/27/2002
All Rights Reserved, © Copyright Matsushita Electric Works,1L1td5.
Go To Online Catalog