English
Language : 

TX2-12V Datasheet, PDF (1/7 Pages) Nais(Matsushita Electric Works) – 2 A CAPACITY RELAY WITH HIGH SURGE VOLTAGE & HIGH BREAKDOWN VOLTAGE
2 A CAPACITY RELAY
WITH HIGH SURGE
VOLTAGE & HIGH
BREAKDOWN VOLTAGE
TESTING
TX RELAYS
7.4
15
.591
.291
8.2
.323
7.4
15
.291
.591
8.4
.331
mm inch
SPECIFICATIONS
Contact
Arrangement
2 Form C
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
100 mΩ
Contact material
Gold-clad silver alloy
Nominal switching capacity
(resistive load)
2 A 30 V DC
Rating
Max. switching power
(resistive load)
Max. switching voltage
60 W
220 V DC
Max. switching current
2A
Min. switching capacity ❇1
10 µA 10 mV DC
Nominal
operating
power
Single side stable
1 coil latching
2 coil latching
140 mW (1.5 to 24 V DC)
270 mW (48 V DC)
100 mW (1.5 to 24 V DC)
200 mW (1.5 to 24 V DC)
Mechanical (at 180 cpm)
10 8
Expected
life (min.
operations)
Electrical
(at 20 cpm)
2 A 30 V DC
resistive
1 A 30 V DC
resistive
105
5×105
Notes:
❇1This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the ac-
tual load. (SX relays are available for low level load switching [10 µA 1 mV DC –
10 mA 10 V DC])
❇2The upper limit for the ambient temperature is the maximum temperature that
can satisfy the coil temperature rise. Under the packing condition, allowable tem-
perature range is from –40 to +70°C –40°C to +158°F.
Remarks
* Specifications will vary with foreign standards certification ratings.
*1 Measurement at same location as "Initial breakdown voltage" section.
*2 By resistive method, nominal voltage applied to the coil; contact carrying current:
2 A.
*3 Nominal voltage applied to the coil, excluding contact bounce time.
*4 Nominal voltage applied to the coil, excluding contact bounce time without diode.
*5 Half-wave pulse of sine wave: 6 ms; detection time: 10 µs.
*6 Half-wave pulse of sine wave: 6 ms.
*7 Detection time: 10 µs.
*8 Refer to 6. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT.
FEATURES
• Breakdown voltage between contacts and coil: 2,000 V
• Surge withstand between contacts and coil: 2,500 V
• High contact capacity: 2 A 30 V DC
• Surface-mount type available
Characteristics
Initial insulation resistance*1
Min. 1,000 MΩ (at 500 V DC)
Initial
breakdown
voltage
Between open con-
tacts
Between contact sets
Between contact and
coil
1,000 Vrms for 1 min.
(Detection current: 10 mA)
1,000 Vrms for 1 min.
(Detection current: 10 mA)
2,000 Vrms for 1 min.
(Detection current: 10 mA)
Initial surge
voltage
Between open
contacts
(10×160 µs)
Between contacts
and coil (2×10 µs)
1,500 V (FCC Part 68)
2,500 V (Telcordia)
Temperature rise*2 (at 20°C)
Max. 50°C
Operate time [Set time]*3 (at 20°C)
Max. 4 ms (Approx. 2 ms)
[Max. 4 ms (Approx. 2 ms)]
Release time [Reset time]*4 (at
20°C)
Max. 4 ms (Approx. 1 ms)
[Max. 4 ms (Approx. 2 ms)]
Shock resistance
Functional* 5
Destructive*6
Min. 750 m/s2 {75 G}
Min. 1,000 m/s2 {100 G}
Functional* 7
Vibration resistance
Destructive
196 m/s2 {20 G}, 10 to 55 Hz
at double amplitude of 3.3 mm
294 m/s2 {30G}, 10 to 55 Hz
at double amplitude of 5 mm
Conditions for oper-
ation, transport and
storage* 8
(Not freezing and
condensing at low
temperature)
Ambient tem-
perature ❇2
Humidity
–40°C to +85°C (up to 24 V coil)
–40°F to +185°F (up to 24 V coil)
–40°C to +70°C (48 V coil)
–40°F to +158°F (48 V coil)
5 to 85% R.H.
Unit weight
Approx. 2 g .071 oz