English
Language : 

SF2 Datasheet, PDF (1/7 Pages) Nais(Matsushita Electric Works) – POLARISED, MONOSTABLE SAFETY RELAY with (mechanical linked) forced contacts operation
SF
(SF3 pending) (SF3 pending)
(SF3 pending)
POLARISED, MONOSTABLE
SAFETY RELAY with
(mechanical linked) forced
contacts operation
SF-RELAYS
π
53.3±0.3
2.098±.012
25.0
.984
16.5±0.3
.650±.012
53.3±0.3
2.098±.012
25.0
.984
16.5±0.3
.650±.012
53.3±0.3
2.098±.012
33±0.3
1.299±.012
16.5±0.3
.650±.012
mm inch
FEATURES
• Forced operation contacts (2 Form A
2 Form B, 3 Form A 1 Form B)
N.O. and N.C. side contacts are
connected through a card so that one
interacts with the other in movement. In
case of a contact welding, the other
keeps a min. 0.5mm .020inch contact
gap.
• Independent operation contacts
(4 Form A 4 Form B)
Each pair of contacts is free from the
main armature and is independent from
each other. So if a N.O. pair of contacts
are welded, the other 3 N.O. contacts are
not effected (operate properly) That
enables to plan a circuit to detect welding
or go back to the beginning condition.
• Separated chamber structure
(2 Form A 2 Form B, 3 Form A 1 Form B,
4 Form A 4 Form B)
N.O. and N.C. side contacts are put in
each own space surrounded with a card
and a body-separater. That prevents
short circuit between contacts, which is
caused by their springs welding or
damaged.
• UL/CSA, TÜV, SEV approved
(UL/CSA, SEV of SF3 pending)
SPECIFICATIONS
Contact
Type
Arrangement
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Contact material
Rating
(resistive)
Nominal switching
capacity
Max. switching power
Max. switching voltage
Max. carrying current
Expected Mechanical (at 180
life (min. cpm) (resistive)
operations) Electrical (at 20 cpm)
SF2
SF3
SF4
2 Form A 3 Form A 4 Form A
2 Form B 1 Form B 4 Form B
30 mΩ
Gold-flashed silver alloy
6 A 250 V AC, 6 A 30 V DC
1,500 VA, 180 W
30 V DC, 440 V AC
6 A DC, AC
107
3×104*1
105
Coil (at 25°C 77°F)
Nominal operating power
500 mW
Remarks
* Specifications will vary with foreign standards certification ratings.
*1 More than 105 operations when applying the nominal switching capacity to one
side of contact pairs of each Form A contact and Form B contact
*2 Measurement at same location as " Initial breakdown voltage " section
*3 Detection current: 10mA
*4 Excluding contact bounce time
*5 Half-wave pulse of sine wave: 11ms; detection time: 10µs
*6 Half-wave pulse of sine wave: 6ms
*7 Detection time: 10µs
*8 Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 61).
Characteristics (at 25°C 77°F, 50% Relative humidity)
SF2
SF3
SF4
Max. operating speed
180 cpm (at nominal voltage)
Initial insulation resistance*2
Min. 1,000 MΩ at 500 V DC
Between con-
tact sets
2,500 Vrms
Initial break- Between open
down voltage*3 contacts
2,500 Vrms
Between con-
tact and coil
2,500 Vrms
Operate time*4
(at nominal voltage)
Approx. 17 ms Approx. 18 ms
Release time (without diode)*4
(at nominal voltage)
Approx. 7 ms
Approx. 6 ms
Temperature rise
(at nominal voltage)
Max. 45°C with nominal coil voltage
and at 6 A switching current
Shock
resistance
Functional* 5
Destructive*5
Min. 294 m/s2 {30 G}
Min. 980 m/s2 {100 G}
Vibration
resistance
Functional* 7
Destructive
117.6 m/s2 {12 G}, 10 to 55 Hz
at double amplitude of 2 mm
117.6 m/s2 {12 G}, 10 to 55 Hz
at double amplitude of 2 mm
Conditions for oper-
ation, transport and
storage*8
(Not freezing and
condensing at low
temperature)
Ambient
temp.
Humidity
–40°C to +70°C –40°F to +158°F
5 to 85% R.H.
Unit weight
37 g 1.31 oz
47 g 1.66 oz
ORDERING INFORMATION
Ex. SF 2
DC 12 V
Contact arrangement
Coil voltage
2: 2 Form A 2 Form B
3: 3 Form A 1 Form B
4: 4 Form A 4 Form B
DC 5, 9, 12, 18, 21,
24, 36, 48, 60 V
UL/CSA, TÜV, SEV approved type is standard (SF2, SF4)
TÜV approved type is standard (SF3)
TYPICAL APPLICATIONS
• Signal
• Escalator
• Elevator
• Medical Instruments
• Railway
• Factory Automation
258