English
Language : 

RX-RELAYS Datasheet, PDF (1/3 Pages) Nais(Matsushita Electric Works) – SMALL MICRO WAVE RELAY
RX
RX-RELAYS SMALL MICRO WAVE RELAY
20.5
.807
12.4
.488
9.4
.370
• Insertion loss
0
0.1
COM-NC
0.2
mm inch
0.3
COM-NO
• V.S.W.R./ Return loss: 1.2dB or less/
20.8dB or more
2. High sensitivity
• Nominal operating power: 200 mW
3. Small size
• Size: 20.5(L) × 12.4(W) × 9.4(H) mm
.807(L) × .488(W) × .370(H) inch
1. Excellent high frequency character-
istics (~2.5GHz, Impedance 50Ω)
• Insertion loss: 0.2 dB or less
• Isolation: 60 dB or more
0.4
0.5
300kHz
1.5GHz
2.5GHz 3GHz
Frequency
*Also available for unit support (contact us
for more details).
SPECIFICATIONS
Contact
Arrangement
1 Form C
Contact material
Initial contact resistance
Contact rating
Gold
Max. 100 mΩ
10W (2.5 GHz, Impedance
50 Ω, V.S.W.R. 1.2)
10mA 24V DC(resistive load)
Rating
Contact carrying power
Max. 20W(at 40°C,
V.S.W.R. 1.2, Average)
Max. switching voltage
30 V DC
Max. switching current
0.5 A DC
Isolation
High frequency Insertion loss
characteristics
(~2.5GHz,
V.S.W.R.(Return loss)
Impedance 50Ω) Input power
Min. 60 dB
Max. 0.2 dB
Max. 1.2 (Min. 20.8dB)
Max. 20W (at 40°C,
V.S.W.R. 1.2,Average)
Mechanical (at 180 cpm)
5×106
Expected
life (min.
operations)
10mA 24 V DC
(resistive load)
Electrical 10W 2.5 GHz,
Impedance 50Ω
3×105
105
Coil (at 20°C, 68°F)
Single side stable
1 coil latching
2 coil latching
Nominal operating power
200 mW
200 mW
400 mW
Characteristics
Initial insulation resistance*1
Min. 100 MΩ (at 500 V DC)
Between open contacts
Initial
breakdown
Between contact and coil
voltage*2 Between contact and
earth terminal
500 Vrms
1,000 Vrms
500 Vrms
Operate time [Set time]*3 (at 20°C)
Max. 10ms (Approx. 6ms)
[Max. 10ms (Approx. 5ms)]
Release time (without diode) [Reset time]*3
Temperature rise (at 20°C)*4
Shock resistance
Functional*5
Destructive*6
Max. 6ms (Approx. 3ms)
[Max. 10ms (Approx. 5ms)]
Max. 60°C
Min. 200 m/s2 {20 G}
Min. 1,000 m/s2 {100 G}
Vibration
resistance
Functional*7
Destructive
10 to 55 Hz
at double amplitude of 3 mm
10 to 55 Hz
at double amplitude of 5 mm
Conditions for operation,
transport and storage*8
Ambient temp.
(Not freezing and condensing
at low temperature)
Humidity
–40°C to 60°C
–40°F to 140°F
5 to 85% R.H.
Unit weight
Approx. 5 g .18 oz
Remarks
* Specifications will vary with foreign standards certification ratings.
*1 Measurement at same location as “Initial breakdown voltage” section.
*2 Detection current: 10mA
*3 Nominal operating voltage applied to the coil, excluding contact bounce time.
*4 By resistive method, nominal voltage applied to the coil: Contact carrying power:
20W, at 2.5GHz, Impedance 50Ω, V.S.W.R.&1.2
*5 Half-wave pulse of sine wave: 11ms, detection time: 10µs.
*6 Half-wave pulse of sine wave: 6ms
*7 Detection time: 10µs
*8 Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 61)
TYPICAL APPLICATIONS
• Cellular phone base station (W-CDMA,
FPLMTS, IMT-2000, PCS, DCS)
• Cellular phone-related measurement
devices (SP3T/SP4T switches, etc)
• Wireless LAN
• Wireless Local Loop
90
ORDERING INFORMATION
Ex. A
RX
1
0
12
Product name Contact arrangement
Operating function
RX
1: 1 Form C
0: Single side stable
1: 1 coil latching
2: 2 coil latching
Note: Standard packing; Carton: 50 pcs. Case 500 pcs.
Coil voltage, V DC
03: 3 09: 9
4H: 4.5 12: 12
06: 6 24: 24