English
Language : 

RA-RELAYS Datasheet, PDF (1/3 Pages) Nais(Matsushita Electric Works) – MICROWAVE RELAY FOR ATTENUATOR CIRCUIT
RA
MICROWAVE RELAY
FOR ATTENUATOR
CIRCUIT
RA-RELAYS
14.70
.579
9.7
.382
5.9
.232
mm inch
FEATURES
1. High frequency characteristics
(Impedance 50Ω, ~1.0GHz)
• Insertion loss; Max. 0.3dB
• Isolation; Min. 20dB (Between open
contacts)
Min. 30dB (Between contact
sets)
• V.S.W.R.; Max. 1.2
2. Surface mount terminal
This relay is a surface-mounted model
with excellent high-frequency proper-
ties. In addition, it can use a microstrip
line in the base circuit design which
spares the labor of machining the base.
3. Low profile small type
9.7(W)×14.7(L)×5.9(H) mm
.382(W)×.579(L)×.232(H) inch
4. High sensitivity: 140 mW nominal
operating power
5. High contact reliability
Electrical life: Min. 107 (10mA 10V DC)
SPECIFICATIONS
Contact
Arrangement
Contact material
Initial contact resistance
Contact rating (resistive)
Rating
High fre-
quency
character-
istics
(~1GHz,
Imped-
ance 50Ω)
Contact carrying power
Max. switching voltage
Max. switching current
Isolation
Between
open con-
tacts
Between
contact
sets
Insertion loss
V.S.W.R.
Input power
Nominal
operating
power
Expected
life (min.
operation)
Single side stable
1 coil latching
2 coil latching
Mechanical (at 180 cpm)
Electrical
(at 20 cpm)
10mA 10 V
DC(resis-
tive load)
1A 30 V DC
(resistive
load)
2 Form C
Gold-clad silver alloy
Max. 75mΩ
10mA 10 V DC
1A 30 V DC
Max. 3W(at 1.0GHz, imped-
ance 50Ω, V.S.W.R. max.1.2)
30 V DC
1A
Min. 20dB
Min. 30dB
Max. 0.3dB
Max. 1.2
Max. 3W(at 1.0GHz, imped-
ance 50Ω, V.S.W.R. max.1.2)
140mW (1.5 to 12V)
200mW (24V)
300mW (48V)
70 mW (1.5 to 12V)
100mW (24V)
140mW (1.5 to 12V)
200mW (24V)
10 8
107
105
Characteristics
Initial insulation resistance *1
Min. 100 MΩ(at 500 V DC)
Between open con-
tacts
750 Vrms for 1 min.
Initial breakdown
voltage *2
Between contact
sets
Between contact
and coil
1,000 Vrms for 1 min.
1,000 Vrms for 1 min.
Between contact
and earth terminal
1,000 Vrms for 1 min.
Operate time [Set time] *3 (at 20°C)
Max. 4ms (Approx. 2ms)
[Max. 4ms (Approx. 2ms)]
Release time (without diode) [Reset time]
*3(at 20°C)
Temperature rise (at 20°C) *4
Shock resistance
Functional *5
Destructive *6
Max. 4ms (Approx. 1ms)
[Max. 4ms (Approx. 2ms)]
Max. 60°C
500 m/s2
1,000 m/s2
Functional *7
Vibration resistance
Destructive
10 to 55 Hz at double
amplitude of 3mm
10 to 55 Hz at double
amplitude of 5mm
Conditions for oper-
ation, transport and
Ambient temp
storage *8
(Not freezing and
condensing at low Humidity
temperature)
–40°C to +85°C
–40°F to +185°F
5 to 85% R.H.
Unit weight
Approx. 2g .07oz
Remarks
* Specifications will vary with foreign standards certification ratings.
*1 Measurement at same location as “Initial breakdown voltage” section.
*2 Detection current: 10mA
*3 Nominal operating voltage applied to the coil, excluding contact bounce time.
*4 By resistive method, nominal voltage applied to the coil: 3W contact carrying
power: at 1.0GHz, Impedance 50Ω, V.S.W.R. Max.1.2
*5 Half-wave pulse of sine wave: 11ms, detection time: 10µs.
*6 Half-wave pulse of sine wave: 6ms
*7 Detection time: 10µs
*8 Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 61)
TYPICAL APPLICATIONS
• Measurement instruments
Oscilloscope attenuator circuit
80
ORDERING INFORMATION
Ex. A RA
2
0
0
A
03
Product name Contact arrangement Operating function Type of operation Terminal shape
RA
2: 2 Form C 0: Single side stable 0: Standard A: Surface-mount
1: 1 coil latching type
terminal
2: 2 coil latching (B.B.M)
Note: Standard packing; Carton: 40 pcs. Case 1,000 pcs.
Coil voltage, V DC
1H: 1.5
03: 3
4H: 4.5
05: 5
06: 6
09: 9
12: 12
24: 24
48: 48