JV1APF-S-12V Datasheet, PDF (1/4 Pages) Nais(Matsushita Electric Works) – FLAT TYPE POWER RELAY
JV-RELAYS FLAT TYPE POWER RELAY
22
.866
16
.630
10.9
.429
mm inch
FEATURES
• Flat type: 16 mm (length) × 22 mm (width) × 10.9 mm (height)
(.630×.866×.429 inch)
• High capacity type (16A) available
• High sensitivity type (100 mW: 1 Form A) available
• TÜV also approved
SPECIFICATIONS
Contact
Arrangement
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Contact material
Nominal switching
capacity
Rating Max. switching power
(resistive)
Max. switching voltage
Max. switching current
Expected life (min. ope.)
Mechanical at (180 cpm)
Electrical at resistive Sealed type
(at 20 cpm)
Flux-resistant
(at rated load)
type
Standard type
1 Form A
1 Form C
High capacity
High
type
sensitivity type
1 Form A
1 Form A
50 mΩ
Silver alloy
10 A 125 V AC
10 A 125 V AC (N.O.)
6 A 125 V AC (N.C.)
16 A 125 V AC
10 A 125 V AC
1,250 VA
1,250 VA (N.O.)
750 VA (N.C.)
2,000 VA
1,250 V
125 V AC
10 A
10 A (N.O.)
6 A (N.C.)
16 A
10 A
107
10 5
105
3×104
5×104
3×105
105
105
105
Coil
1 Form A type
Nominal
operating
power
Standard type
High capacity type
High sensitivity type
200 mW (up to 48 V coil type)
600 mW (100 V coil type)
100 mW
1 Form C type
400 mW (up to 48 V coil type)
600 mW (100 V coil type)
—
—
Remarks
* Specifications will vary with foreign standards certification ratings.
*1 Measurement at same location as "Initial breakdown voltage"section
*2 Detection current: 10mA
*3 Excluding contact bounce time
*4 Half-wave pulse of sine wave: 11ms, detection time: 10µs
*5 Half-wave pulse of sine wave: 6ms
*6 Detection time: 10µs
*7 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 24).
*8 100V type: –40 to + 60°C –40 to + 140°F
TYPICAL APPLICATIONS
1. Home appliances: Air conditioner, heater, etc.
2. Automotive: Power supply for car stereo and air conditioner
Characteristics
Max. operating speed
20 cpm
Initial insulation resis-
tance* 1
Min. 100 MΩ
(at 500 V DC)
Initial Between open
break- contacts
down Between con-
voltage*2 tacts and coil
1,000 Vrms
for 1 min.
1,500 Vrms
for 1 min.
Operate time*3
(at nominal voltage)
Approx. 10 ms
Approx. 5 ms
(100 V DC coil type)
Release time (without diode)*3
(at nominal voltage)
Approx. 4 ms
Temperature rise
(at 50°C)
Max. 65°C with nominal
coil voltage across
coil and at nominal
switching capacity
Functional*4 Min. 98 m/s2 {10 G}
Shock
resistance Destructive*5
Min. 980 m/s2
{100 G}
Functional* 6
Vibration
resistance
Destructive
10 to 55 Hz
at double amplitude
of 1.0 mm
10 to 55 Hz
at double amplitude
of 1.6 mm
Conditions for opera- Ambient
tion, transport and temp.
storage*7
(Not freezing and
condensing at low Humidity
temperature)
–40°C to +70°C*8
–40°F to +158°F
5 to 85%R.H.
Unit weight
Approx. 8 g .282 oz
ORDERING INFORMATION
Ex. JV 1a
P
F
S
12V
Contact arrangement
1: 1 Form C
1a: 1 Form A
Rating
Nil: Standard type
P: High capacity type*
Protective construction
Nil: Sealed type
F: Flux-resistant type
Sensitivity
Nil: Standard type
(1 Form A: 200 mW, 1Form C: 400 mW
100 V DC coil type: 600 mW)
S: High sensitivity type*
(1 Form A: 100 mW)
Coil voltage (DC)
5, 6, 9, 12, 18,
24, 48, 100V
Notes: 1. Standard packing: Carton: 50 pcs.; Case: 1,000 pcs.
2. Coil voltage DC 48, 100 V types are not available for high sensitivity type.
UL/CSA, TÜV approved type is standard.
* Only for 1 Form A type
87