English
Language : 

JR1A-TM-AC115 Datasheet, PDF (1/4 Pages) Nais(Matsushita Electric Works) – SLIM TYPE POWER RELAYS
JR-RELAYS SLIM TYPE POWER RELAYS
28.6
1.126
12.8
.504
28.5
1.122
High contact
capacity type
mm inch
TMP type
TM type
FEATURES
• AC coil types and high capacity (16 A) types
• Wide insulation distance: 8 mm .315 inch between coil and
contact
• High dielectric withstanding for transient protection: JR can
withstand 10,000 V surge in µs between coil and contact.
• High inrush current capability: 1 Form A: 111 A inrush (TV-5),
• Slim package for tandem mounting: Header area is 28.6 mm
× 12.8 mm 1.126×.504 inch
• Molded materials: all 94 V-0
• "TM" and "TMP" types available
• TÜV also approved
SPECIFICATIONS
Contact
AC coil type
High capacity
type
Arrangement
1 Form A
Initial contact resistance
max.
(By voltage drop 6 V DC 1 A)
30 mΩ
Contact material
Silver alloy
Rating
(resistive)
Nominal switching capacity
10 A 250 V AC
10 A 30 V DC
16 A 250 V AC
16 A 30 V DC
Maximum switching power 2,500 VA, 300 W 4,000 VA, 480 W
Maximum switching voltage 250 V AC, 30 V DC 250 V AC, 30 V DC
Maximum switching current
10 A
16 A
Mechanical (180 cpm)
Expected
life (min. Electrical 16 A 250 V AC
operations)
(resistive)
(20 cpm)
10 A 250 V AC
5×106
—
10 5
105
—
Coil
Nominal operating power
1.1 VA/0.9 VA
(at 50Hz/60Hz)
530mW
Remarks
* Specifications will vary with foreign standards certification ratings.
*1 Detection current: 10mA
*2 Wave is standard shock voltage of ±1.2 × 50µs according to JEC-212-1981
*3 With nominal coil voltage and at maximum switching current
*4 Half-wave pulse of sine wave: 11ms; detection time: 10µs
*5 Half-wave pulse of sine wave: 6ms
*6 Detection time: 10µs
*7 Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 24).
Characteristics
Maximum operating speed
Initial insulation resistance
Initial
Between open contacts
breakdown
voltage*1 Between contacts and coil
Initial surge voltage between
coil and contact*2
Operate time
(at nominal voltage)(at 20°C)
Release time (without diode)
(at nominal voltage)(at 20°C)
Temperature rise*3
(at nominal voltage)
Shock
Functional* 4
resistance Destructive*5
Functional* 6
Vibration
resistance
Destructive
Conditions for operation, Ambient
transport and storage*7 temp.
(Not freezing and condens-
ing at low temperature) Humidity
Unit weight
AC coil type High capacity type
20 cpm
Min. 1,000 MΩ at 500 V DC
1,000 Vrms for 1 min.
5,000 Vrms for 1 min.
Min. 10,000 V
Approx. 10 ms
Approx. 6 ms
Approx. 2 ms
Max. 60°C
(10 A, at 20°C)
Max. 45°C
(16 A, at 20°C)
Min. 98 m/s2 {10 G}
Min. 980 m/s2 {100 G}
88.2 m/s2 {9 G}, 10 to 55 Hz
at double amplitude of 1.5 mm
117.6 m/s2 {12 G}, 10 to 55 Hz
at double amplitude of 2.0 mm
–50°C to +55°C –50°C to +70°C
–58°F to +131°F –58°F to +158°F
5 to 85% R.H.
Approx. 20 g .71 oz
TYPICAL APPLICATIONS
• Microwave ovens
• Refrigerators
• Copiers
• Facsimiles
• Air conditioners
• Stereo equipment
• TV sets
• Vending machines
• Temperature controllers
98
ORDERING INFORMATION
Ex. JR 1a
TM
DC12V
Contact arrangement
Mounting method
1a: 1 Form A
1aF: High contact capacity
(1 Form A)
TM: Top mounting
Nil: PCB terminal
TM: Top mounting
TMP: Solder and PC teminal
Notes: 1. For UL/CSA recognized types, add suffix UL/CSA.
Notes: 2. Standard packing: Carton: 100 pcs. Case: 500 pcs.
Notes: 3. 18 V DC type are also available. Please consult us for details.
Coil voltage
AC 115 V
DC 5, 6, 12, 24, 48 V