ARD1004H Datasheet, PDF (1/8 Pages) Nais(Matsushita Electric Works) – 26.5GHz, 18GHz COAXIAL SWITCH | |||
|
26.5GHz, 18GHz
COAXIAL SWITCH
RD
RD COAXIAL
SWITCHES
â
â Transfer type is coming soon.
FEATURES
1. High frequency characteristics
(Impedance 50â¦)
Frequency
(GHz)
â1
â4
â8 â12.4 â18 â26.5*
V.S.W.R.
(max.)
1.1 1.15 1.25 1.35
1.5
1.7
Insertion
loss
0.2
(dB. max.)
0.3 0.4 0.5 0.8
Isolation
(dB. min.)
85
80
70
65
60
55
*: 18 to 26.5GHz characteristics can be applied
26.5GHz type only
2. SPDT and transfer type available
3. High sensitivity
Nominal operating power:
840 mW (SPDT, Failsafe type)
1540 mW (Transfer, Failsafe type)
4. Long life: 5 Ã 106 (SPDT)
TYPICAL APPLICATIONS
Wireless and mobile communication
infrastructure
⢠Cellular phone base stations
⢠Ampliï¬er switching
Measurement instruments
⢠All types of inspection equipment
ATTENTION
Transfer type is coming soon.
SPECIFICATIONS
Contact
Arrangement
Contact material
Initial contact resistance
Rating
Contact input power*1
Indicator rating
Contact rating
Initial contact resistance
(Measured by 5V 100mA)
High frequency
characteristics
(Impedance 50â¦)
Expected life
(min. operation)
V.S.W.R. (max.)
Insertion loss (dB, max.)
Isolation (dB, min.)
Mechanical (at 180 cpm)
Electrical (at 20 cpm)
SPDT
Transfer
Gold plating
Max. 100mâ¦
120W 3GHz
(V.S.W.R 1.15 or less, no contact switching, ambient temperature 40°C [SPDT], 25°C [Transfer])
Max. 30V 100mA
Max. 5V 100mA
Max. 1â¦
to 1 GHz
1.1
0.2
85
1 to 4
1.15
80
4 to 8
1.25
0.3
70
5 à 106 (5W, to 3GHz, impedance 50â¦,
V.S.W.R.; max. 1.2)
8 to12.4
12.4 to 18 18 to 26.5
1.35
1.5
1.7
0.4
0.5
0.8
65
60
55
5 Ã 106
106 (5W, to 3GHz, impedance 50â¦,
V.S.W.R.; max. 1.2)
Characteristics
Initial insulation resistance*2
Between open contacts
Initial breakdown Between contact and coil
voltage*3
Between contact and earth terminal
Between coil and earth terminal
Operate time*4 (at 20°C)
Shock resistance
Functional*5
Destructive*6
Vibration resistance
Functional*7
Destructive
Conditions for operation, transport and storage*8 Ambient temp
(Not freezing and condensing at low temperature) Humidity
Unit weight (Approx.)
Remarks
*1 Please verify the usability of input power under actual conditions because heat
generated from connectors can inï¬uence connection.
*2 Measurement at same location as âInitial breakdown voltageâ section.
*3 Detection current: 10mA
*4 Nominal operating voltage applied to the coil, excluding contact bounce time.
SPDT
Transfer
Min. 1,000 Mâ¦
500 Vrms for 1 min.
500 Vrms for 1 min.
500 Vrms for 1 min.
500 Vrms for 1 min.
Max. 15ms
Max. 20ms
500 m/s2
1,000 m/s2
10 to 55 Hz at double amplitude of 3mm
10 to 55 Hz at double amplitude of 5mm
â55°C to +85°C â67°F to +185°F
5 to 85% R.H.
50g 1.76oz
110g 3.88oz
*5 Half-wave pulse of sine wave: 11ms, detection time: 10µs.
*6 Half-wave pulse of sine wave: 11ms
*7 Detection time: 10µs
*8 Refer to 4. Conditions for operation, transport and storage mentioned in NOTES.
1
|
▷ |