English
Language : 

APE1004H Datasheet, PDF (1/3 Pages) Nais(Matsushita Electric Works) – THE SLIM POWER RELAY
VDE
Pending
PE-RELAYS THE SLIM POWER RELAY
28
1.102
5
.197
15
.591
FEATURES
• Slim size
28 mm (L)×5 mm (W)×15 mm (H)
1.102 inch (L)×.197 inch (W)×.591 inch
(H)
permits high density mounting
• Wide switching capacity:
100 mA/12 V DC-6A/250 V AC
• High sensitivity: 170mW
• High breakdown (4,000 V) and surge
(6,000 V) voltage between contacts
and coil
• Clearance/creepage distance: 8/8 mm
• 1 Form A/1 Form C contact.
Insulation complying to following standards:
EN 60255 General specification for electrical relays
EN 60335 For use in house-hold appliances
EN 60730 For use in temperature sensing appliances
EN 60950 For use in electrical business equipment
EN 60065 For use in entertainment electronics
(radio, HiFi-sets)
EN 50178 For use in industrial range
SPECIFICATIONS
Contacts
Arrangement
Contact material
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Nominal switching capacity
Rating (resis- Maximum switching power
tive)
Maximum switching voltage
Max. switching current
Expected life Mechanical (at 180 cpm)
(min.opera- Electrical (at 6 cpm)
tions)
(at rated load)
1 Form A, 1 Form C
Silver alloy
Au-plated
silver alloy
100 mΩ
30 mΩ
6 A 250 V AC
1,500 VA
400 V AC/300 V DC
6 A (AC)
5×106
N.O.: 5×104
N.C.: 3×104
Coil (at 25°C 77°F, 50% R.H.)
Nominal operating power
170 mW (4.5 to 24 V DC)
217 mW (48 V DC)
Remarks
* Specifications will vary with foreign standards certification ratings.
*1 Measurement at same location as "Intial breakdown voltage" section
*2 Detection current: 10mA
*3 Wave is standard shock voltage of ±1.2×50µs according to JEC-212-1981
*4 Excluding contact bounce time
*5 Half-wave pulse of sine wave: 50ms; detection time: 10µs
*6 Half-wave pulse of sine wave: 11ms
*7 Detection time: 10µs
*8 Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 61).
Characteristics
Initial insulation resistance*1
Min. 1,000 MΩ at 500 V DC
Initial breakdown
voltage* 2
Between open
contacts
Between con-
tacts and coil
1,000 Vrms
4,000 Vrms
Surge voltage between contacts and
coil* 3
Min. 6,000 V (Initial)
Operate time*4 (at nominal voltage)
Max. 8 ms (approx. 5 ms)
Release time (without diode)*4
(at nominal voltage)
Max. 4 ms (approx. 2.5 ms)
Temperature rise
Max. 30°C with nominal coil
voltage across
coil and at nominal switching
capacity
Shock resistance
Functional* 5
Destructive*6
1 Form C: Min. 49 m/s2{5 G}
1 Form A: Min. 98 m/s2{10 G}
Min. 980 m/s2 {100 G}
Vibration resistance
Functional* 7
Destructive
10 to 55 Hz
at double amplitude of 1.0 mm/6 G
10 to 55 Hz
at double amplitude of 1.5 mm/9 G
Conditions for operation,
transport and storage*8
(Not freezing and condens-
ing at low temperature)
Ambient
temp.
Humidity
–40°C to +85°C
–40°F to +185°F
5 to 85%R.H.
Unit weight
Approx. 4 g .14 oz
TYPICAL APPLICATIONS
• Interface relays for programmable con-
trollers
• Output relays for measuring equipment,
timers, counters and temperature con-
trollers
• Industrial equipment, office equipment
• House-hold appliances for Europe
ORDERING INFORMATION
Ex. APE
0
Contact arrangement
1: 1 Form A
3: 1 Form C
Contact type
0: Single contact
Contact material
0: Silver alloy
1: Au-plated silver alloy
(Notes) 1. Standard packing: Tube: 20 pcs.; Case: 1,000 pcs.
2. 5 V, 60 V type is also available.
3. 1 Form B is also available.
Coil voltage (DC)
4H: 4.5 V 18: 18 V
06: 6 V 24: 24 V
12: 12 V 48: 48 V
211