English
Language : 

ALD14H Datasheet, PDF (1/3 Pages) Nais(Matsushita Electric Works) – 1 Form A Slim Power Relay
LD VDE
LD-RELAYS 1 Form A Slim Power Relay
FEATURES
7.0
20.3
.276
.799
1. Slim type: Width 7 mm .276 inch.
20.3(L)×7.0(W)×15.0(H) mm
4. High shock resistance
The relay withstands a functional shock
15.0
.799(L)×.276(W)×.591(H) inch
resistance of 300m/s2 [approx. 30 G
.591
2. Perfect for small load switching of
more]
home appliances
5. High insulation resistance
105 switching operations possible with a
• Creepage distance and clearances be-
3A 250V AC resistive load.
tween contact and coil: Min. 6 mm .236
mm inch
3. Low operating power
Compact size, nominal operating power
as low as 200mW.
inch(In compliance with IEC65)
• Surge withstand voltage between con-
tact and coil: 10,000 V or more.
6. UL/CSA, VDE, TÜV approved.
SPECIFICATIONS
Contact
Arrangement
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Contact material
Nominal switching capacity
Rating
(resistive load)
Max. switching power
Max. switching voltage
Max. switching current
Mechanical (at 180 cpm)
Expected life Electrical
3A 125V AC,
(min.operations) (at 20 cpm) 3A 30V DC
(at rated load) 3A 250V AC
1 Form A
Max. 100 mΩ
Silver alloy
3 A 277 V AC, 3 A
30V DC
831 V A (AC),
90W (DC)
277 V AC, 30 V DC
3A
5×106
2×105
10 5
Coil
Nominal operating power
200 mW
Remarks
* Specifications will vary with foreign standards certification ratings.
*1 Measurement at same location as "Initial breakdown voltage" section.
*2 Detection current: 10mA
*3 Wave is standard shock voltage of ±1.2×50ms according to JEC-212-1981
*4 Excluding contact bounce time.
*5 Half-wave pulse of sine wave: 11 ms; detection time: 10 µs
*6 Half-wave pulse of sine wave: 6 ms
*7 Detection time: 10 µs
*8 Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 24).
Characteristics
Max. operating speed
Initial insulation resistance*1
Initial* 2
breakdown
voltage
Between open
contacts
Between contact and
coil
Initial surge voltage between contact
and coil*3
Operate time*4 (at nominal voltage)
Release time (with diode)*4
(at nominal voltage)
Temperature rise (at 70°C)
Shock resistance
Functional* 5
Destructive*6
Vibration resistance
Functional* 7
Destructive
Conditions for operation,
transport and storage*8
(Not freezing and con-
densing at low tempera-
ture)
Unit weight
Ambient
temp.
Humidity
20 cpm (at rated load)
Min. 1,000 MΩ (at 500 V DC)
750 Vrms for 1 min.
4,000 Vrms for 1 min.
Min. 10,000 V
Max. 10ms (at 20°C 68°F)
Max. 10ms (at 20°C 68°F)
Max. 45°C with nominal coil
voltage and at 3 A contact
carrying current
(resistance method)
Min. 300 m/s2{approx. 30 G}
Min. 1,000 m/s2{approx. 100 G}
10 to 55Hz
at double amplitude of 1.5mm
10 to 55Hz
at double amplitude of 1.5mm
–40°C to +70°C
–40°F to +158°F
5 to 85% R.H.
Approx. 4 g .141 oz
TYPICAL
APPLICATIONS
• Air conditioner
• Refrigerator
• Hot water units
• Microwave ovens
• Fan heaters
ORDERING INFORMATION
Ex.
A
LD
1
Product name
LD
Contact arrangement
1: 1 Form A
UL/CSA, TÜV approved type is standard.
Note: Standard packing: Carton: 50pcs, Case: 1,000pcs
12
Coil voltage(V DC)
4H: 4.5, 09: 9, 24: 24
05: 5, 12: 12
06: 6, 18: 18
47