UVQ_SERIES Datasheet, PDF (7/25 Pages) Murata Manufacturing Co., Ltd. – Low Profi le, Isolated Quarter Brick 2.5 40 Amp DC/DC Converters | |||
|
◁ |
UVQ Series
Low Proï¬le, Isolated Quarter Brick
2.5â40 Amp DC/DC Converters
Performance/Functional Speciï¬cations 48V Models
Typical @ TA = +25°C under nominal line voltage, nominal output voltage, natural air convection, external caps and full-load conditions, unless noted. (1)
Input
Input voltage range
Start-up threshold, min (V)
Undervoltage
shutdown, (V)14
Overvoltage shutdown (V)
Reï¬ected (back) ripple
current
Input Current
Full load conditions
Inrush transient, (A2sec)
0.05
Output short circuit, (mA)
No load, mA
100
Low line (VIN = min.),
(Amps)
3.15
Standby mode,
(Off, UV, OT shutdown)
Internal input ï¬lter type
Reverse polarity
protection
Remote On/Off Control5
Positive logic, "P" sufï¬x
(speciï¬cations are max)
Negative logic, "N" sufï¬x
(speciï¬cations are max)
Current
See ordering guide
35
34.5
34
34.5
35
33.5
32
33.5
none
10-50 mA pk-pk, model dependent
0.05
1
50
130
80
See ordering guide.
1
0.05
1
0.05
0.05
10
30
50
250
50
60
30
80
45
30
3.56
3.07
3.72
3.21
3.35
3.30
3.60
1-4mA, model dependent
L-C
Pi-type
L-C
See notes.
OFF = Ground pin to +0.8V
ON = Open or +5V to +VIN max
OFF = Open or +5V to +VIN max
ON = Ground pin to+0.8V max
1-8 mA, model dependent
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_UVQ Models.B11 Page 7 of 25
|
▷ |