ULE20A Datasheet, PDF (4/23 Pages) Murata Manufacturing Co., Ltd. – Isolated, High Density, Eighth-Brick | |||
|
◁ |
ISOLATION CHARACTERISTICS
ULE Series
Isolated, High Density, Eighth-Brick
1.25â30 Amp, DC/DC Converters
DYNAMIC CHARACTERISTICS
Model Family
ULE-1.2/30-D48
ULE-1.5/20-D24
ULE-1.5/20-D48
ULE-1.8/20-D24
ULE-1.8/20-D48
ULE-2.5/20-D24
ULE-2.5/20-D48
ULE-3.3/20-D12
ULE-3.3/20-D24
ULE-3.3/20-D48
ULE-5/10-D12
ULE-5/12-D24
ULE-5/12-D48
ULE-12/4.2-D24
ULE-12/4.2-D48
ULE-24/3-D48
ULE-48/1.25-D48
Input to
Output
Min.
(V)
Isolation Isolation
Resistance Capacitance Isolation
(MΩ)
(pF) Safety Rating
2000-
2250 min.,
model
100
dependent
1750
Basic
Insulation
470
1750
2000
1500
Model Family
ULE-1.2/30-D48
ULE-1.5/20-D24
ULE-1.5/20-D48
ULE-1.8/20-D24
ULE-1.8/20-D48
ULE-2.5/20-D24
ULE-2.5/20-D48
ULE-3.3/20-D12
ULE-3.3/20-D24
ULE-3.3/20-D48
ULE-5/10-D12
ULE-5/12-D24
ULE-5/12-D48
ULE-12/4.2-D24
ULE-12/4.2-D48
ULE-24/3-D48
ULE-48/1.25-D48
Dynamic Load Response
(50-75-50% load step)
100μSec to ±1% of ï¬nal value
100μSec to ±1.5% of ï¬nal value
100μSec to ±1.5% of ï¬nal value
100μSec to ±1.5% of ï¬nal value
100μSec to ±1.5% of ï¬nal value
150μSec to ±1% of ï¬nal value
80μSec to ±1.5% of ï¬nal value
150μSec to ±1.25% of ï¬nal value
150μSec to ±1.5% of ï¬nal value
150μSec to ±1% of ï¬nal value
75μSec to ±2% of ï¬nal value
75μSec to ±2% of ï¬nal value
100μSec to ±1% of ï¬nal value
150μSec to ±1.25% of ï¬nal value
150μSec to ±1.25% of ï¬nal value
200μSec to ±2% of ï¬nal value
200μSec to ±1% of ï¬nal value
Switching
Frequency
KHz
260±15
280±15
280±15
340±15
340±15
385±15
385±45
310±15
385±15
365±15
325±15
450±15
450±15
400±15
380±15
240±30
250±15
MISCELLANEOUS CHARACTERISTICS
Model Family
ULE-1.2/30-D48
ULE-1.5/20-D24
ULE-1.5/20-D48
ULE-1.8/20-D24
ULE-1.8/20-D48
ULE-2.5/20-D24
ULE-2.5/20-D48
ULE-3.3/20-D12
ULE-3.3/20-D24
ULE-3.3/20-D48
ULE-5/10-D12
ULE-5/12-D24
ULE-5/12-D48
ULE-12/4.2-D24
ULE-12/4.2-D48
ULE-24/3-D48*
ULE-48/1.25-D48
Operating Temperature Range
Calculated
MTBF
See
derating curves
Operating PCB Storage
Thermal
Temperature Temperature Protection/
(no derating) Range Shutdown
TBC
â40 to +85ºC with derating
â40 to
+105ºC
â55 to
+125ºC
+105 to
+125ºC,
model
dependent
*No derating is required up to 85°C.
See notes on page 5.
www.murata-ps.com
Short
Circuit
Current
3A
3A
3A
3A
3A
3A
3A
300mA
3A
3A
5A
5A
2A
3A
3A
0.65A
500mA
Overvoltage
Protection12
via magnetic Short Circuit
feedback Protection
(V) Method
Short Circuit
Duration16
Relative
Humidity
2.0
2.3
2.0
2.3
2.3
3.5
3.0
Current
3.96
3.96
3.96
limiting,
hiccup
autorestart.
Remove
overload for
Continuous,
output
shorted to
ground.
No damage.
To
+85ºC/85%
non-
condensing
6.0
recovery
6.0
6.4
15.0
14.0
28.0
55.0
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_ULE Series.C11 Page 4 of 23
|
▷ |