English
Language : 

ULE20A Datasheet, PDF (4/23 Pages) Murata Manufacturing Co., Ltd. – Isolated, High Density, Eighth-Brick
ISOLATION CHARACTERISTICS
ULE Series
Isolated, High Density, Eighth-Brick
1.25–30 Amp, DC/DC Converters
DYNAMIC CHARACTERISTICS
Model Family
ULE-1.2/30-D48
ULE-1.5/20-D24
ULE-1.5/20-D48
ULE-1.8/20-D24
ULE-1.8/20-D48
ULE-2.5/20-D24
ULE-2.5/20-D48
ULE-3.3/20-D12
ULE-3.3/20-D24
ULE-3.3/20-D48
ULE-5/10-D12
ULE-5/12-D24
ULE-5/12-D48
ULE-12/4.2-D24
ULE-12/4.2-D48
ULE-24/3-D48
ULE-48/1.25-D48
Input to
Output
Min.
(V)
Isolation Isolation
Resistance Capacitance Isolation
(MΩ)
(pF) Safety Rating
2000-
2250 min.,
model
100
dependent
1750
Basic
Insulation
470
1750
2000
1500
Model Family
ULE-1.2/30-D48
ULE-1.5/20-D24
ULE-1.5/20-D48
ULE-1.8/20-D24
ULE-1.8/20-D48
ULE-2.5/20-D24
ULE-2.5/20-D48
ULE-3.3/20-D12
ULE-3.3/20-D24
ULE-3.3/20-D48
ULE-5/10-D12
ULE-5/12-D24
ULE-5/12-D48
ULE-12/4.2-D24
ULE-12/4.2-D48
ULE-24/3-D48
ULE-48/1.25-D48
Dynamic Load Response
(50-75-50% load step)
100μSec to ±1% of final value
100μSec to ±1.5% of final value
100μSec to ±1.5% of final value
100μSec to ±1.5% of final value
100μSec to ±1.5% of final value
150μSec to ±1% of final value
80μSec to ±1.5% of final value
150μSec to ±1.25% of final value
150μSec to ±1.5% of final value
150μSec to ±1% of final value
75μSec to ±2% of final value
75μSec to ±2% of final value
100μSec to ±1% of final value
150μSec to ±1.25% of final value
150μSec to ±1.25% of final value
200μSec to ±2% of final value
200μSec to ±1% of final value
Switching
Frequency
KHz
260±15
280±15
280±15
340±15
340±15
385±15
385±45
310±15
385±15
365±15
325±15
450±15
450±15
400±15
380±15
240±30
250±15
MISCELLANEOUS CHARACTERISTICS
Model Family
ULE-1.2/30-D48
ULE-1.5/20-D24
ULE-1.5/20-D48
ULE-1.8/20-D24
ULE-1.8/20-D48
ULE-2.5/20-D24
ULE-2.5/20-D48
ULE-3.3/20-D12
ULE-3.3/20-D24
ULE-3.3/20-D48
ULE-5/10-D12
ULE-5/12-D24
ULE-5/12-D48
ULE-12/4.2-D24
ULE-12/4.2-D48
ULE-24/3-D48*
ULE-48/1.25-D48
Operating Temperature Range
Calculated
MTBF
See
derating curves
Operating PCB Storage
Thermal
Temperature Temperature Protection/
(no derating) Range Shutdown
TBC
−40 to +85ºC with derating
−40 to
+105ºC
−55 to
+125ºC
+105 to
+125ºC,
model
dependent
*No derating is required up to 85°C.
See notes on page 5.
www.murata-ps.com
Short
Circuit
Current
3A
3A
3A
3A
3A
3A
3A
300mA
3A
3A
5A
5A
2A
3A
3A
0.65A
500mA
Overvoltage
Protection12
via magnetic Short Circuit
feedback Protection
(V) Method
Short Circuit
Duration16
Relative
Humidity
2.0
2.3
2.0
2.3
2.3
3.5
3.0
Current
3.96
3.96
3.96
limiting,
hiccup
autorestart.
Remove
overload for
Continuous,
output
shorted to
ground.
No damage.
To
+85ºC/85%
non-
condensing
6.0
recovery
6.0
6.4
15.0
14.0
28.0
55.0
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000