English
Language : 

LSN2-T30-D12 Datasheet, PDF (2/17 Pages) Murata Manufacturing Co., Ltd. – DOSA-SIP, 30A POL DC/DC Converters
LSN2-T/30-D12 Series
DOSA-SIP, 30A POL DC/DC Converters
PERFORMANCE SPECIFICATIONS AND ORDERING GUIDE ➀
Output
Model ➆
VOUT
IOUT
Power
(Volts) (Amps) (Watts)
R/N (mVp-p) ➁
Typ. Max.
LSN2-T/30-D12-C 0.8-5
30
150
25
50
Regulation (max.) ➂
Line
Load
±0.1% ±0.1%
VIN Nom.
(Volts)
12
Input
Range➅
(Volts)
6-14
IIN ➃
(mA/A)
200/11.1
Efficiency ➄
Min. Typ.
93% 94%
Package
(Case/
Pinout)
B13, P71
➀ Typical at TA = +25°C under nominal line voltage and full-load conditions, unless noted. All
models are tested and specified with external 22μF tantalum input and output 0.01//0.1//10μF
capacitors. These capacitors are necessary to accommodate our test equipment and may not
be required to achieve specified performance in your applications. See I/O Filtering and
Noise Reduction.
➁ Ripple/Noise (R/N) is tested/specified over a 20MHz bandwidth for VOUT > 3.63V and may be
reduced with external filtering. See I/O Filtering and Noise Reduction for details.
➂ These devices have no minimum-load requirements and will regulate under no-load conditions.
Regulation specifications describe the output-voltage deviation as the line voltage or load is
varied from its nominal/midpoint value to either extreme.
➃ Nominal line voltage, no-load/full-load conditions.
➄ LSN2-T/30-D12 efficiencies are shown at 5VOUT.
➅ Input range is 6-14V if VOUT ≤3.63V. For VOUT > 3.63V, the input range is 7–14V.
➆ Please refer to the Part Number Structure for additional options when ordering.
PART NUMBER STRUCTURE
L SN2 - T / 30 - D12 G - C
Output Configuration:
L = Unipolar
Low Voltage
Non-Isolated Through-hole
RoHS-6 hazardous
substance compliant
Power Good:
Blank = Omitted (default)
G = Installed (special quantity orders required)
Nominal Output Voltage:
0.8-5 Volts
Maximum Rated Output
Current in Amps
Input Voltage Range:
D12 = 7-14 Volts (12V nominal)
Note:
Some model number combina-
tions may not be available. Contact
Murata Power Solutions.
SOLDERING GUIDELINES
Murata Power Solutions recommends the specifications below when installing these converters. These specifications vary depending on the solder type.
Exceeding these specifications may cause damage to the product. Be cautious when there is high atmospheric humidity. We strongly recommend a mild
pre-bake (100ºC. for 30 minutes). Your production environment may differ therefore please thoroughly review these guidelines with your process engineers.
Wave Solder Operations for through-hole mounted products (THMT)
For Sn/Ag/Cu based solders:
Maximum Preheat Temperature
Maximum Pot Temperature
Maximum Solder Dwell Time
115ºC.
270ºC.
7 seconds
For Sn/Pb based solders:
Maximum Preheat Temperature
Maximum Pot Temperature
Maximum Solder Dwell Time
105ºC.
250ºC.
6 seconds
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_LSN2-T/30-D12 Series.B17 Page 2 of 17