WPN20R12S05C Datasheet, PDF (1/4 Pages) Murata Manufacturing Co., Ltd. – 20W Regulated DC/DC Converter | |||
|
WPN20
20W Regulated DC/DC Converter
FEATURES
RoHS compliant
Operating temperature range: -40ºC to
+100ºC
Industry standard pinout
Input and output ï¬ltering
Low proï¬le shell
Single and dual outputs
Output trim function
DESCRIPTION
The WPN20RC series is available in three input
voltage ranges of 9-18V, 18-36V and 33-75V. The
unit is housed in a space saving aluminum shell.
The 300KHz switching frequency and forward
converter topology provide excellent performance
across all line and load conditions. Other features
include: under voltage lock-out, internal tem-
perature shutdown, soft start and over current
protection.
An output trim feature is provided, allowing the
user to compensate for long line lengths.
Applications include: Telecommunications, Battery
Powered Sytems, Process Control Equipment,
Transportation Equipment and Distributed Power
Systems.
The product range has been recognised by Under-
writers Laboratory (UL) to UL 1950 for operational
insulation, ï¬le number E179522 applies.
SELECTION GUIDE
Order Code
WPN20R12S05C
WPN20R12S12C
WPN20R12D12C
WPN20R24S03C
WPN20R24S05C
WPN20R24S12C
WPN20R24D12C
WPN20R24D15C
WPN20R48S05C
WPN20R48S12C
WPN20R48D12C
WPN20R48D15C
Input Voltage
Nom.
V
12
12
12
24
24
24
24
24
48
48
48
48
Output
Voltage
V
5.0
12.0
±12.0
3.3
5.0
12.0
±12.0
±15.0
5.0
12.0
±12.0
±15.0
Output Current
Min.
Nom.
A
A
0.0
4.00
0.0
1.66
0.0
±0.83
0.0
6.00
0.0
4.00
0.0
1.66
0.0
±0.83
0.0
±0.67
0.0
4.00
0.0
1.66
0.0
±0.83
0.0
±0.67
Input Current
Efï¬ciency
Nom. Load
A
%
2.00
84
2.00
86
2.00
86
1.00
83
1.00
84
1.00
87
1.00
87
1.00
87
0.50
85
0.50
88
0.50
87
0.50
87
INPUT CHARACTERISTICS
Parameter
Conditions
All WPN20R12 types
Voltage range
All WPN20R24 types
All WPN20R48 types
Reï¬ected ripple current
Undervoltage lockout
threshold
All WPN20R12 types
All WPN20R24 types
All WPN20R48 types
Min. Typ. Max. Units
9
12
18
18
24
36
V
33
48
75
50 mA p-p
7
8.8
15.5
17
V
30
33
OUTPUT CHARACTERISTICS
Parameter
Conditions
Rated power
Voltage setpoint accuracy
Temperature coefï¬cient
Line regulation
Singles
High line to low line
Duals
Load regulation
Min load to
Nom. load
Singles
Duals
Ripple & Noise
Single outputs, BW = 5Hz to 20MHz
Dual outputs, BW = 5Hz to 20MHz
Output voltage adjust range See attached plots
Short circuit &
overcurrent protection
Continuous
Min. Typ. Max. Units
20
W
±1.5
%
±0.005 %/ºC
±0.1
%
±0.5
%
±0.5
%
±2.0
%
60
100 mVp-p
50
100 mVp-p
GENERAL CHARACTERISTICS
Parameter
Conditions
Switching frequency
Max capacitive load
MTTF per ML-HDBK-217 Circuit stress method
Ground benign
TA = +25º unmodiï¬ed database
Min. Typ. Max. Units
300
kHz
550
mF/A
1.4
MHr
All speciï¬cations typical at TA=25°C, nominal input voltage and rated output current unless otherwise speciï¬ed.
Ḥ
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com
Technical enquiries - email: mk@murata-ps.com, tel: +44 (0)1908 615232
KDC_WPN20RC.C01 Page 1 of 4
|
▷ |