English
Language : 

WPN20R12S05C Datasheet, PDF (1/4 Pages) Murata Manufacturing Co., Ltd. – 20W Regulated DC/DC Converter
WPN20
20W Regulated DC/DC Converter
FEATURES
RoHS compliant
Operating temperature range: -40ºC to
+100ºC
Industry standard pinout
Input and output filtering
Low profile shell
Single and dual outputs
Output trim function
DESCRIPTION
The WPN20RC series is available in three input
voltage ranges of 9-18V, 18-36V and 33-75V. The
unit is housed in a space saving aluminum shell.
The 300KHz switching frequency and forward
converter topology provide excellent performance
across all line and load conditions. Other features
include: under voltage lock-out, internal tem-
perature shutdown, soft start and over current
protection.
An output trim feature is provided, allowing the
user to compensate for long line lengths.
Applications include: Telecommunications, Battery
Powered Sytems, Process Control Equipment,
Transportation Equipment and Distributed Power
Systems.
The product range has been recognised by Under-
writers Laboratory (UL) to UL 1950 for operational
insulation, file number E179522 applies.
SELECTION GUIDE
Order Code
WPN20R12S05C
WPN20R12S12C
WPN20R12D12C
WPN20R24S03C
WPN20R24S05C
WPN20R24S12C
WPN20R24D12C
WPN20R24D15C
WPN20R48S05C
WPN20R48S12C
WPN20R48D12C
WPN20R48D15C
Input Voltage
Nom.
V
12
12
12
24
24
24
24
24
48
48
48
48
Output
Voltage
V
5.0
12.0
±12.0
3.3
5.0
12.0
±12.0
±15.0
5.0
12.0
±12.0
±15.0
Output Current
Min.
Nom.
A
A
0.0
4.00
0.0
1.66
0.0
±0.83
0.0
6.00
0.0
4.00
0.0
1.66
0.0
±0.83
0.0
±0.67
0.0
4.00
0.0
1.66
0.0
±0.83
0.0
±0.67
Input Current
Efficiency
Nom. Load
A
%
2.00
84
2.00
86
2.00
86
1.00
83
1.00
84
1.00
87
1.00
87
1.00
87
0.50
85
0.50
88
0.50
87
0.50
87
INPUT CHARACTERISTICS
Parameter
Conditions
All WPN20R12 types
Voltage range
All WPN20R24 types
All WPN20R48 types
Reflected ripple current
Undervoltage lockout
threshold
All WPN20R12 types
All WPN20R24 types
All WPN20R48 types
Min. Typ. Max. Units
9
12
18
18
24
36
V
33
48
75
50 mA p-p
7
8.8
15.5
17
V
30
33
OUTPUT CHARACTERISTICS
Parameter
Conditions
Rated power
Voltage setpoint accuracy
Temperature coefficient
Line regulation
Singles
High line to low line
Duals
Load regulation
Min load to
Nom. load
Singles
Duals
Ripple & Noise
Single outputs, BW = 5Hz to 20MHz
Dual outputs, BW = 5Hz to 20MHz
Output voltage adjust range See attached plots
Short circuit &
overcurrent protection
Continuous
Min. Typ. Max. Units
20
W
±1.5
%
±0.005 %/ºC
±0.1
%
±0.5
%
±0.5
%
±2.0
%
60
100 mVp-p
50
100 mVp-p
GENERAL CHARACTERISTICS
Parameter
Conditions
Switching frequency
Max capacitive load
MTTF per ML-HDBK-217 Circuit stress method
Ground benign
TA = +25º unmodified database
Min. Typ. Max. Units
300
kHz
550
mF/A
1.4
MHr
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
Ḥ
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com
Technical enquiries - email: mk@murata-ps.com, tel: +44 (0)1908 615232
KDC_WPN20RC.C01 Page 1 of 4