English
Language : 

UEE Datasheet, PDF (1/29 Pages) Murata Manufacturing Co., Ltd. – Isolated, High-Density, Eighth-Brick DOSA Low Profi le DC/DC Converters
www.murata-ps.com
Output (V)
3.3
3.3
3.3
UEE Series
Isolated, High-Density, Eighth-Brick
DOSA Low Profile DC/DC Converters
Current (A)
Nominal Input (V)
15
48
25
48
30
48
Typical units
FEATURES
■Interleaved synchronous rectification yields high
efficiency over 90%
■36 to 75 Vdc input range (48V nominal)
■Outstanding thermal performance and derating
■Low profile 0.40" height with 0.9" x 2.3" outline
dimensions
■Fully isolated, 2250 Vdc (BASIC) insulation
■Industry standard DOSA eighth-brick pinout and
package and surface mount (SMT) option
■Extensive self-protection and short circuit
features
■On/Off control, trim and sense functions
■Fully protected against temperature and voltage
limits
■RoHS-6 compliant
■Certification is pending for UL/EN/IEC 60950-1
and CAN/CSA C22.2 No. 60950-1, 2nd Edition
safety approvals
For efficient, fully isolated DC power in the smallest space, the UEE
open frame DC/DC converter series fit in industry-standard “eighth
brick” outline dimensions and mounting pins (on quarter-brick pinout)
or surface mount option.
PRODUCT OVERVIEW
Units are offered with a fixed output voltage and
current up to 30 Amps. UEEs operate over a wide
temperature range (up to +85 degrees Celsius at
moderate airflow) with full rated power. Interleaved
synchronous rectifier topology yields excellent
efficiency.
UEEs achieve these impressive mechanical and
environmental specs while delivering excellent
electrical performance in an industry standard
DOSA compatible through-hole package or surface
mount option. The unit is fully protected against
input undervoltage, output overcurrent and short
circuit. An on-board temperature sensor shuts
down the converter if thermal limits are reached
and automatically restarts the converter when the
fault is removed.
An On/Off control input enables phased startup
and shutdown in multi-voltage applications. UEEs
include a Sense input to correct for ohmic losses. A
trim input may be connected to a user’s adjustment
potentiometer or trim resistors for output voltage
calibration.
UEEs include industry-standard safety certifi-
cations and BASIC I/O insulation provides input/
output isolation to 2250V. Radiation and conducted
emission testing is performed to widely accepted
EMC standards.
F1
+Vin (1)
External
DC
Power
Source
On/Off
Control
(2)
Open = On
polarity)
-Vin (3)
Ḥ
For full details go to
www.murata-ps.com/rohs
Barrier
Controller
and Power
Reference and
Error Amplifier
Figure 1. Connection Diagram
Typical topology is shown. Murata Power Solutions recommends an external fuse.
+Vout (8)
Trim (6)
-Vout (4)
(some models pending
certification)
www.murata-ps.com/support
MDC_UEE_Series.A04 Page 1 of 29