English
Language : 

TPS_CPCI200A-1 Datasheet, PDF (1/4 Pages) Murata Manufacturing Co., Ltd. – 200W 3Ux4HP AC/DC CompactPCI
cPCI200A-1C Series
200W 3Ux4HP AC/DC CompactPCI™
SELECTION GUIDE
Model Number
Power
CPCI200A-1C
200W
Output Current
Ḥ
5V 3.3V 12V -12V
For full details go to
www.murata-ps.com/rohs
25A 30A 5A 1A
Yes
Yes
INPUT CHARACTERISTICS
Parameter
Conditions
Min
Input Operating Voltage
90
Input Frequency
47
Input Current
FEATURES
3Ux4HP package
200W power at 0-50ºC
Power Factor
0.95
Inrush Current
240Vac
Leakage Current
240VAC, 63Hz
PICMG 2.11 Compliant
Widerange 90-264VAC Input
Active power factor correction to EN61000-3-2
Class A conducted EMI performance
47-pin I/O Connector
80% efficiency
OUTPUT CHARACTERISTICS
Output
V12
V22
V3
V4
Nominal Voltage
+5.0Vdc
+3.3Vdc
+12Vdc
-12Vdc
Output Current
Min
Max
1A3
25A
1 A3
30A
0A
5A
0A
1A
Full power with just 250lfm airflow
Hot-swap capable
Parameter
Temperature Coefficient
PARD (V1 & V2)
Conditions
20MHz bandwidth
Min
Typ
50
DESCRIPTION
The cPCI200A-1C is a high-reliability, 200W, 3Ux4HP
CompactPCI™ power supply developed for chassis’
with airflows as low as 250lfm. The use of resonant
conversion and ORing FETs yields high efficiency which
consequently permits packaging of this product in a
compact, single card slot format (4HP).
The ORing FETs, current sharing, and synchronous start
control allow the cPCI200A-1C to be operated in N+n
parallel-redundant configurations. The low leakage
current permits redundant configurations to comply
with safety standards. The unit is capable of hot-swap
performance to support high-availability enterprise
applications.
With a widerange input of 90-264VAC, safety
agency approvals to UL60950 and EN60950, EMI
compliance to Class A FCC and EN55022 standards,
the cPCI200A-1C was designed with globally-deployed
systems in mind. Additional features include remote
sense compensation, unit enable control (EN#), output
inhibit control (INH#), output fault signal (FAL#), and
thermal warning signal (DEG#). LEDs are provided for
visual indication of input power presence and output
fault condition.
PARD (V3 & V4)
Output Power
Output Power
Transient Response
Over-Voltage Protection
Minimum Load4
Output Holdup Time
Remote Sense Compensation5
Current Share Tolerance
Isolation
20MHz bandwidth
50ºC, 250lfm airflow
70ºC, 250lfm airflow
ΔV, 50% load step
Settling time
V1, V2, & V3
V1 or V2
Full load, low line
V1, V2, & V3
V1-V3; Io>25%
Pri-Sec
Pri-Chassis
Sec-Chassis
120
0
0
125
1
12
250
3
1.5
500
Notes:
1. Total regulation includes line, load, and cross regulation.
2. Maximum combined power from V1 & V2 not to exceed 125W.
3. Minimum load requirement of 1A may be fulfilled on either V1 or V2, but need not be applied to both.
The unit will operate with less than the stated minimum, but full load on V3 & V4 is only achievable with
the minimum load requirement met on V1 and/or V2.
4. Minimum load is for a single unit; units operated in parallel may require additional load to achieve full
power on outputs V3 and V4.
5. Unit automatically reverts to local sensing if the sense lines are opened. Unit is protected against shorted
or reversed sense lines.
Typ Max Units
264 Vac
63 Hz
3.5
Arms
0.98 0.99
35
Apk
1
mA
Total Regulation1
+4/-2%
+4/-2%
±4%
±4%
Max
Units
0.02
%/ºC
mVp-p
180
mVp-p
200
W
100
W
±5
%Vnom
500
μsec
135
%Vnom
A
16
msec
mV
10
%
kVac
kVac
Vac
www.murata-ps.com
cPCI200A-1C Series Rev D 02/2008 Page 1 of 4