English
Language : 

SF2224E Datasheet, PDF (1/5 Pages) RF Monolithics, Inc – 1950 MHz SAW Filter
• Low-loss 1950 MHz SAW Filter
• Complies with Directive 2002/95/EC (RoHS)
Pb
Absolute Maximum Ratings
Rating
Input Power Level
DC Voltage on any Non-ground Terminal
Operating Temperature Range
Storage Temperature Range in Tape and Reel
Maximum Soldering Profile, 5 cycles/10 seconds maximum
Value
+13
3
-40 to +85
-40 to +85
265
Units
dBm
V
°C
°C
°C
SF2224E
1950 MHz
SAW Filter
Electrical Characteristics
Characteristic
Center Frequency
Insertion Loss, 1920 to 1980 MHz
Amplitude Ripple, 1920 to 1980 MHz
Input/Output VSWR, 1920 to 1980 MHz
Attenuation, Referenced to 0 dB:
DC to 1840 MHz
1840 to 1900 MHz
2000 to 2030 MHz
2030 to 2060 MHz
2060 to 5000 MHz
Source Impedance
Load Impedance
Case Style
Lid Symbolization (Y=year, WW=week, S=shift) dot=pin 1 indicator
Standard Reel Quantity
Reel Size 7 inch
Reel Size 13 inch
Electrical Connections
Connection
Terminals
Input
2
Output
5
Case Ground
All others
SM3030-6
Sym Notes
Min
fC
IL
Typ
1950
2.3
1.4
1.7
Max
4.0
2.4
2.4
20.0
32.0
10.0
21.0
4.5
10.0
20.0
47.0
22.0
29.0
ZS
50
ZL
50
SM3030-6 3.0 x 3.0 mm Nominal Footprint
960, YWWS
500 Pieces/Reel
3000 Pieces/Reel
Units
MHz
dB
dBP-P
dB
Ω
Ω
CAUTION: Electrostatic Sensitive Device. Observe precautions for handling.
Notes:
1. Unless noted otherwise, all specifications apply over the operating temperature range with filter soldered to the specified demonstration board with impedance
matching to 50 Ω and measured with 50 Ω network analyzer.
2. Unless noted otherwise, all frequency specifications are referenced to the nominal center frequency, fc.
3. Rejection is measured as attenuation below the minimum IL point in the passband. Rejection in final user application is dependent on PCB layout and external
impedance matching design. See Application Note No. 42 for details.
4. "LRIP" or "L" after the part number indicates "low rate initial production" and "ENG" or "E" indicates "engineering prototypes."
5. The design, manufacturing process, and specifications of this filter are subject to change.
6. Either Port 1 or Port 2 may be used for either input or output in the design. However, impedances and impedance matching may vary between Port 1 and Port
2, so that the filter must always be installed in one direction per the circuit design.
7. US and international patents may apply.
8. RFM, stylized RFM logo, and RF Monolithics, Inc. are registered trademarks of RF Monolithics, Inc.
www.RFM.com E-mail: info@rfm.com
©2010 by RF Monolithics, Inc.
Page 1 of 5
SF2224E - 7/19/10