English
Language : 

SF2143A Datasheet, PDF (1/5 Pages) RF Monolithics, Inc – Designed for SDARS IF Receiver
Preliminary
• Designed for SDARS IF Receiver
• SAW Diplexer 72.54 / 80.46 MHz
• 11.4 X 5.3 mm Surface-Mount Case
• Complies with Directive 2002/95/EC (RoHS)
Pb
SF2143A
72.54/80.46 MHz
SAW Diplexer
Absolute Maximum Ratings
Rating
Maximum Incident Power in Passband
Maximum DC Voltage between any Two Terminals
Operating Temperature Range
Value
+10
0
-40 to +105
Units
dBm
VDC
°C
Electrical Characteristics
SM11453-10
TDM1 Filter Characteristic
Nominal Center Frequency
1 dB Bandwidth
15 dB Bandwidth
30 dB Bandwidth
Passband Minimum Insertion Loss including the Matching Network
Amplitude Ripple, FC ± 1.85 MHz
Attenuation Relative to ILMIN
50.00 to 66.48 MHz
66.48 to 68.08 MHz
77.30 to 78.60 MHz
78.60 to 86.50 MHz
86.50 to 91.50 MHz
91.50 to 100.0 MHz
Group Delay Ripple
Source Impedance (Differential)
Load Impedance (Differential)
Sym
FC
BW1
BW15
BW30
ILMIN
Notes
1
Min
Typ
Max
72.54
3.7
4.3
5.5
6.7
6.0
7.7
15.3
18
0.7
40
49
37
42
37
40
40
45
45
61
45
66
83
27 ohms or 200 ohms
1K ohms or 1.5K ohms
Units
MHz
MHz
MHz
MHz
dB
dBP-P
dB
dB
dB
dB
dB
dB
nsP-P
TDM2 Filter Characteristic
Nominal Center Frequency
1 dB Bandwidth
15 dB Bandwidth
30 dB Bandwidth
Passband Minimum Insertion Loss including the Matching Network
Amplitude Ripple, FC ± 1.85 MHz
Attenuation Relative to ILMIN
50.00 to 74.39 MHz
74.39 to 75.99 MHz
85.21 to 86.50 MHz
86.50 to 91.50 MHz
91.50 to 100.0 MHz
Group Delay Ripple
Source Impedance (Differential)
Load Impedance (Differential)
Sym
FC
BW1
BW15
BW30
ILMIN
Notes
1
Min
Typ
Max
80.46
3.7
4.3
5.5
6.7
6.4
7.7
15.7
19.5
1.5
34
41
30
35
40
42
43
44
45
56
120
27 ohms or 200 ohms
1K ohms or 1.5K ohms
Units
MHz
MHz
MHz
MHz
dB
dBP-P
dB
dB
dB
dB
dB
nsP-P
Case Style
6
Lid Symbolization (YY=year, WW=week, S=shift) See note 4
CAUTION: Electrostatic Sensitive Device. Observe precautions for handling.
Notes:
SM11453 11.4 x 5.3 mm Nominal Footprint
RFM SF2143A YYWWS
1. Unless noted otherwise, all specifications apply over the operating temperature range with filter soldered to the specified demonstration board with impedance
matching to 50 Ω and measured with 50 Ω network analyzer.
2. Unless noted otherwise, all frequency specifications are referenced to the nominal center frequency, fc.
3. Rejection is measured as attenuation below the minimum IL point in the passband. Rejection in final user application is dependent on PCB layout and external
impedance matching design. See Application Note No. 42 for details.
4. "LRIP" or "L" after the part number indicates "low rate initial production" and "ENG" or "E" indicates "engineering prototypes."
5. The design, manufacturing process, and specifications of this filter are subject to change.
6. Tape and Reel Standard ANSI / EIA 481.
7. Either Port 1 or Port 2 may be used for either input or output in the design. However, impedances and impedance matching may vary between Port 1 and Port
2, so that the filter must always be installed in one direction per the circuit design.
8. US and international patents may apply.
9. RFM, stylized RFM logo, and RF Monolithics, Inc. are registered trademarks of RF Monolithics, Inc.
10. ©Copyright 2009, RF Monolithics Inc.
www.RFM.com E-mail: info@rfm.com
©2009 by RF Monolithics, Inc.
Page 1 of 5
SF2143A - 2/2/09