FEATURES
ï®ï Small package: SMD/TH: 30.85 x 20.0 x 8.2 mm
(1.215 x 0.787 x 0.323 in); SIP: 33.0 x 7.6 x 18.1 mm
(1.30 x 0.30 x 0.713 in)
ï®ï 0.6 V - 3.3 V output voltage range
ï®ï High efï¬ciency, typ. 97.2% at 5Vin, 3.3Vout half
load
ï®ï Conï¬guration and monitoring via PMBusâ¢
ï®ï Synchonization & phase spreading
ï®ï Current sharing, voltage tracking & voltage
margining
ï®ï Voltage setting via pin-strap or PMBusâ¢
ï®ï MTBF 14.2 Mh
ï®ï Non-Linear Response for reduction of decou-
pling capacitor
ï®ï Remote control & power good
ï®ï Output short-circuit, output over voltage, & over
temperature protection
ï®ï Certiï¬ed to UL/IEC 60950-1
PRODUCT OVERVIEW
The OKDx-T/40-W12 series are high efï¬-
ciency, digital point-of-Load (PoL) DC-DC
power converters capable of delivering
40A/132W. Available in three different pack-
age formats, through-hole, single-in-line,
and surface mount, these converters have a
typical efï¬ciency of 97.2%. PMBus⢠compat-
ibility allows monitoring and conï¬guration of
critical system-level performance require-
ments. Apart from standard PoL performance
and safety features like OVP, OCP, OTP, and
UVLO, these digital converters have advanced
features: digital current sharing (full power,
no derating), non-linear transient response,
optimized dead time control, synchronization,
and phase spreading. These converters are
ideal for use in telecommunications, network-
ing, and distributed power applications.
Power Management via PMBusâ¢
ï®ï Conï¬gurable soft-start/stop
ï®ï Conï¬gurable output voltage (Vout) and voltage
margins (Margin low and Margin high)
ï®ï Conï¬gurable protection limits for OVP, input over
voltage, input under voltage, over current, on/off,
and temperature
ï®ï Status monitor Vout, Iout, Vin, Temp, Power
good, and On/Off
Applications
ï®ï Distributed power architectures
ï®ï Intermediate bus voltage applications
ï®ï Servers and storage applications
ï®ï Network equipment
PART NUMBER STRUCTURE
OKD x - T / 40 - W12 - xxx - C
Digital Non-isolated PoL
Y = Surface Mount
H = Horizontal Mount Through-Hole
X = SIP
Trimmable Output
Voltage Range
0.6 - 3.3Vdc
RoHS Hazardous
Substance Compliance
C = RoHS-6 (does not claim EU RoHS exemption
7b â lead in solder)
Software Conï¬guration Digits
(001 is positive turn-on logic)
Maximum Rated Output
Current in Amps
Input Voltage Range
4.5-14Vdc