English
Language : 

NPH25S2415EIC Datasheet, PDF (1/8 Pages) Murata Manufacturing Co., Ltd. – Isolated 25W Single Output DC/DC Converters
www.murata-ps.com NOT RECOMMENDED
NPH25S Series
FOR NEW DESIGNSIsolated 25W Single Output DC/DC Converters
FEATURES
„ RoHS compliant
„ High efficiency to 89%
„ Power density up to 1.78W/cm3
„ UL94 V-0 package material
„ Industry standard pinout
„ UL 1950 recognized
„ Non latching current limit
„ Constant 350kHz frequency
„ 1.5kV input to output isolation
„ Versatile control options
„ Continuous rating to 30W at 60ºC without
heatsink
„ Operation to zero load
„ Protected against load faults
„ Internal over temperature protection
„ Uses no electrolytic capacitors
DESCRIPTION
The NPH25S series of DC/DC converters combines
ease of application with versatility. The pin pattern
is based on the popular industry standard, but two
additional pins may optionally be fitted to provide
a variety of features not commonly found on units
of this type. High efficiency enables full rating to
be achieved in a small package without heat-
sinking, and a high surge capability will provide
for start-up and transient loads, whilst being
thermally protected against sustained overload.
Overload protection of the “constant current” type
ensures start-up into complex load conditions. The
copper case achieves efficient heat transfer and
screening. The product range has been recog-
nised by Underwriters Laboratory (UL) to UL 1950
for operational insulation, file number E151252
applies.
Ḥ
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
SELECTION GUIDE
Order Code1
Nominal Input
Voltage
V
V
NPH25S2403EiC
24
3.4
NPH25S2403iC
24
3.4
NPH25S2405EiC
24
5.1
NPH25S2405iC
24
5.1
NPH25S2412EiC
24
12.1
NPH25S2412iC
24
12.1
NPH25S2415EiC
24
15.1
NPH25S2415iC
24
15.1
NPH25S4803EiC
48
3.4
NPH25S4803iC
48
3.4
NPH25S4805EiC
48
5.1
NPH25S4805iC
48
5.1
NPH25S4812EiC
48
12.1
NPH25S4812iC
48
12.1
NPH25S4815EiC
48
15.1
NPH25S4815iC
48
15.1
Current Limit
A A (Min.) A (Max.) %
7.3
7.5
11.0 81
7.3
7.5
11.0 81
5.0
5.0
7.5 84
5.0
5.0
7.5 84
2.1
2.5
3.7 86
2.1
2.5
3.7 86
1.7
2.0
3.0 87
1.7
2.0
3.0 87
Obsolete
7.3
7.5
11.0 83
7.3
7.5
11.0 83
5.0
5.0
7.5 85
5.0
5.0
7.5 85
2.1
2.5
3.7 88
2.1
2.5
3.7 88
1.7
2.0
3.0 89
1.7
2.0
3.0 89
MTTF2
kHrs
334
334
290
290
291
291
290
290
Recommended
Alternative
UEI30-033-Q48N-C
UEI30-033-Q48N-C
UEI30-050-Q48N-C
UEI30-050-Q48N-C
UEI30-120-Q48N-C
UEI30-120-Q48N-C
UEI30-150-Q48N-C
UEI30-150-Q48N-C
369 UEI25-033-D48P-C
369 UEI25-033-D48P-C
366 UEI25-050-D48P-C
366 UEI25-050-D48P-C
368 UEI25-120-D48P-C
368 UEI25-120-D48P-C
366 Contact Murata
366 Contact Murata
INPUT CHARACTERISTICS
Parameter
Conditions
Voltage range
Continuous operation, 24V input types
Continuous operation, 48V input types
Min. Typ. Max. Units
18
24
36
V
36
48
75
OUTPUT CHARACTERISTICS
Parameter
Conditions
Min. Typ. Max. Units
Voltage set point error
50% load
0.5
%
Overall voltage error
Case temperature -40ºC to 110ºC
Load 0% - 100%, Input specified range
2.5
%
Temperature coefficient of
output voltage (slope)
250 ppmºC
Deviation of output voltage Temperature MIN-MAX
0.5
1
%
Line regulation
Load Regulation
Operating voltage range, 50% load
0% - 100% rated load
0.1
%
0.5
Ripple
rms
70
mV
ISOLATION CHARACTERISTICS
Parameter
Conditions
Isolation test voltage
Flash tested for 1 second
Resistance
VISO = 500VDC
Min. Typ. Max. Units
1500
VDC
1
GΩ
ABSOLUTE MAXIMUM RATINGS
Input voltage, 24V input types
Input voltage, 48V input types
Output voltage
Output trim control
Synchronisation/shutdown control
-0.5V to 40V3
-0.5V to 80V3
-0.3V to regulated voltage
-1V to +30V
±15V relative to input return
1. Parts ending with EiC have optional TRIM and SS pins fitted.
2. Calculated using MIL-HDBK-217F with nominal input voltage at full load.
3. Absolute maximum value for 30 seconds. Prolonged operation may damage the product.
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
KDC_NPH25S.H01 Page 1 of 8