|
NDS6S2405C Datasheet, PDF (1/6 Pages) Murata Manufacturing Co., Ltd. – Isolated 6W Wide Input Single & Dual Output DC/DC Converters | |||
|
www.murata-ps.com
NDS6 Series
Isolated 6W Wide Input Single & Dual Output DC/DC Converters
FEATURES
 UL 60950 recognized
 RoHS compliant
 2:1 Wide range voltage input
 Operating temperature range
â40°C to 85°C
 Short circuit protection
 0.003% Typical load regulation
 1.5kVDC Isolation
 Efï¬ciency from 81%
 24V Nominal input
 Single & dual outputs
 Power density 0.94W/cm3
 Optional remote On/Off
 UL 94V-0 Package materials
 No electrolytic capacitors
 Low noise
PRODUCT OVERVIEW
The NDS6 series of DC/DC converters offer single
and dual output voltages from an input voltage
range of 18-36V. The NDS6 is housed in an indus-
try standard package with a standard pinout. The
NDS6 is packaged in a metal case for improved
EMI shielding and is also encapsulated for supe-
rior thermal performance. Versions with optional
remote on/off control pin are also available.
Applications include telecommunications, battery
powered systems, process control and distributed
power systems.
SELECTION GUIDE
Input
Voltage
Order Code2
Nom.
V
NDS6D2405C 24
NDS6D2412C 24
NDS6D2415C 24
NDS6S2405C 24
NDS6S2412C 24
NDS6S2415C 24
Output
Voltage
V
±5
±12
±15
5
12
15
Output Current
Min. ±100%
Load Load
A
A
±0.06 ±0.6
±0.025 ±0.250
±0.020 ±0.200
0.12 1.2
0.05 0.5
0.04 0.4
Input Current
Current
Efï¬ciency
Ripple
0%
Load
100%
Load
Shut & Noise
Down
Min.
Typ.
mA mA mA mV p-p % %
7 300 1.1 40 81 83
7 290 1.1 40 85 87
7 290 1.1 45 85 87.5
4 305 1.1 40 81 82
5.5 290 1.1 40 85.5 87
6 290 1.1 40 85.5 87
MTTF1
kHrs
INPUT CHARACTERISTICS
Parameter
Conditions
Voltage range
All NDS6D24 & NDS6S24 types
Reï¬ected ripple current All NDS6D24 & NDS6S24 types
Min. Typ. Max. Units
18
24
36
V
7
mA p-p
OUTPUT CHARACTERISTICS
Parameter
Conditions
Rated power
Postive & negative except
Voltage set point accuracy
NDS6D2405 negative output
Line regulation
Low line to high line
Load regulation
10% total load to 100% total load
Cross regulation
% voltage change on negative
output when positive load varies
from 12.5% to 37.5% with
negative load ï¬xed at 50%
5V
12V & 15V
Min. Typ. Max. Units
6
W
±2
%
±4
0.01 0.1
%
0.003 0.5
%
5
%
2
ISOLATION CHARACTERISTICS
Parameter
Conditions
Isolation test voltage
Flash tested for 1 second
Resistance
Viso = 1kVDC
Capacitance
Min. Typ. Max. Units
1500
VDC
1
GΩ
225
pF
ABSOLUTE MAXIMUM RATINGS
Short-circuit protection
Internal power dissipation
Lead temperature 1.0mm from case for 10 seconds (to JEDEC JESD22-B106 ISS C)
Minimum output load for speciï¬cation3
Control pin input voltage
Input voltage, NDS6 24V input types
Continuous
2.7W
260°C
10% of rated load on each output
±18V
40V
1 Calculated using MIL-HDBK-217F with nominal input voltage at full load.
2 To order with optional control pin, preï¬x C with âEâ. For example NDS6D0505EC.
3 Operation below 10% minimum load may cause increased output ripple.
All speciï¬cations typical at TA=25°C, nominal input voltage and rated output current unless otherwise speciï¬ed.
Ḥ
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
KDC_NDS6.C05 Page 1 of 6
|
▷ |