English
Language : 

MVAB120-48 Datasheet, PDF (1/7 Pages) Murata Manufacturing Co., Ltd. – 120W 2" x 4" AC-DC Power Supply Converter
www.murata-ps.com
MVAB120 Series
120W 2" x 4" AC-DC Power Supply Converter
FEATURES
ITE (2nd) and Medical 3rd ed. 1MOPP (primary-
secondary) safety approved
120W compact high density
2" x 4" standard footprint
High efficiency up to 91%
Universal AC input with active PFC
Low profile - 1U package
Convection-cooled operation up to 75W
RoHS compliant
UL Class I and II approved (for IT equipment)
DESCRIPTION
The MVAB120 series switching power supplies
utilize advanced component and circuit
technologies to deliver high efficiency. Designed
for Medical, Telecom, and Industrial applications
to satisfy 1U height design considerations, the
MVAB120 Series measures only 2.0" x 4.0"
x 1.35". All models offer universal AC input
with active power factor correction (PFC) and
compliance to worldwide safety and EMC
standards.
www.murata-ps.com/en/3d/acdc.html
www.murata-ps.com/en/3d/acdc.html
www.murata-ps.com/en/3d/acdc.html
www.murata-ps.com/en/3d/acdc.html
www.murata-ps.com/en/3d/acdc.html
www.murata-ps.com/en/3d/acdc.html
Available now at
www.murata-ps.com/en/3d/acdc.html
ORDERING GUIDE
Model Number
MVAB120-12
MVAB120-12-01
MVAB120-24
MVAB120-24-01
MVAB120-28
MVAB120-28-01
MVAB120-48
MVAB120-48-01
Medical Approval1 Natural Convection Cooling
No
Yes
No
Yes
No
75W
Yes
No
Yes
Forced Air Cooling
120W @ 250LFM
Main Output
(V1)
12V
24V
28V
48V
INPUT CHARACTERISTICS
Parameter
Input Voltage Operating Range
Input Frequency
Turn-on Input Voltage
Turn-off Input Voltage
Input Current
Inrush Current
Conditions
Single phase
DC1
Input rising at 75W
Input falling at 75W
90Vac input, full load
At 264Vac, at 25°C cold
start
Min. Typ. Max. Units
90 120/230 264
Vac
120
300
Vdc
47 50/60 63
Hz
76
85
Vac
50
1.9
A
75
Apk
OUTPUT CHARACTERISTICS
Model Number
Main Output
Voltage (V1)
MVAB120-12
MVAB120-12-01
12V
MVAB120-24
MVAB120-24-01
24V
MVAB120-28
MVAB120-28-01
28V
MVAB120-48
MVAB120-48-01
48V
Load Current
0 to 10.0A
0 to 5.0A
0 to 4.29A
0 to 2.5A
Load Capacitance
0 to 3300μF
0 to 1000μF
0 to 1000μF
0 to 1000μF
Line, Load, Cross
Regulation
± 2%
± 2%
± 2%
± 2%
Typical Efficiency
@230Vac full load
88%
90%
90%
91%
MAIN OUTPUT CHARACTERISTICS (ALL MODELS)
Parameter
Conditions
Min. Max. Units
Transient Response
50% load step, 1A/μsec slew rate
±5
%
Settling Time to 1% of Nominal
MVAB120-12
MVAB120-24, MVAB120-28, MVAB120-48
750
μsec
500
μsec
Turn On Delay
After application of input power
1
sec
Output Voltage Rise
Monotonic, 0 to 75W
50
msec
Setpoint Accuracy
120Vac, 75W, 25°C
± 0.5
%
Output Holdup
Full load
14
msec
Temperature Coefficient
Ripple Voltage & Noise2
0.02 %/°C
1
%
1 Medical versions not designed for DC input voltage.
2 Ripple and noise are measured with 0.1 μF of ceramic capacitance and 47 μF of electrolytic capacitance on each
of the power supply outputs. The output noise requirements apply over a 0 Hz to 20 MHz bandwidth. A short
coaxial cable with 50Ω scope termination is used.
3 Unless otherwise specified, all readings are taken at 120Vac input and 25°C ambient temperature.
Ḥ
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
CB
Test Certificate
and Test Report
MVAB120.A13 Page 1 of 7