English
Language : 

MPDTH03050WAH Datasheet, PDF (1/6 Pages) Murata Manufacturing Co., Ltd. – Adjustable Non-isolated 6-Amp
www.murata-ps.com
Typical units
FEATURES
„ Compatible to Point-of-Load Alliance (POLA) Specifications
„ Surface-mount or through-hole small footprint package
„ Three user-selectable output voltage ranges covering 0.8V
to 5.5V
„ Outline dimensions less than one square inch
„ 3.3V, 5V and 12 Vdc nominal inputs
„ High efficiency up to 95% typical
„ Tracking input for sequenced startup/shutdown
„ Outstanding thermal performance and derating
„ -40 to +85 degrees Celsius operating range
„ Extensive self-protection, voltage limits and short circuit
features
„ On/Off control, trim and pre-bias start-up functions
MPDTH***50 Series
Adjustable Non-isolated 6-Amp
POLA DC/DC Converters
DESCRIPTION
The MPDTH series non-isolated DC/DC power modules are small in size but big
on performance and flexibility. Their high output current, compact footprint and
industry-leading features offer system designers versatile modules for powering
complex multi-processor digital systems. Standard inputs are 3.3V., 5V. or 12
Volts DC nominal.
Two mounting styles are offered, either a pinned through-hole model with
slightly lower height or a surface mount model, both with identical length and
width. Respective models all share the same pinout and comply with the POLA
DC/DC converter standard.
The output voltage is adjustable in three ranges from 0.8 V. to 5.5 V and can
be set with a single external resistor. The series also includes Auto-Track
sequencing, enabling modules to track each other’s output voltage in multi-
powered systems during power-up and power-down.
Other operating features include a remote on/off control and the ability to start
up into an existing (prebias) output voltage. Extensive self-protection features
include input under-voltage lockout (UV), output short circuit protection and
output overcurrent shutdown (OC) using an automatic restart. All models meet
RoHS6 hazardous substance compliance.
Track Input
F1
+Vin
External
DC Power
Source
D1
C1: 100μF
C2: 10μF
ceramic
Inhibit
On/Off
Open = On
Closed = Off
3
2
MPDTH_50
Series
4
1
Ground
+Vout
6
VoAdj (Trim)
5
C3: 10μF
Ḥ
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com
Figure 1. Connection Diagram
Notes:
1. Murata Power Solutions strongly recommends an external fuse, F1. Fuse rating = 2 x Iin max.
2. Consider using diode D1 to blow the fuse in case of reversed polarity.
3. C1: 100μF/25V, aluminum electrolytic capacitor, required for all models.
C2: 10μF/25V, ceramic capacitor, required for MPDTH12050 models.
C3: 10μF ceramic, recommended for all models. Voltage rating ≥ 2 x Vout.
4. Track input is referred to ground.
5. See trim information for RSet.
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MPDTH_50 Series.A08 Page 1 of 6