4900 Series
Shielded Dual Winding Surface Mount Inductors
FEATURES
RoHS compliant
2.2μH to 880μH1
Up to 9.5A IDC
Bobbin format
Dual winding
Surface mount
Integral EMI shield
Compact size
Tape and reel packaging
No voltage breakdown at 500VDC
J-STD-020C reflow
Backward compatible with
Sn/Pb soldering systems
DESCRIPTION
The 4900 series is a range of dual wound
inductors offering flexible options. Windings
have a 1:1 ratio and can be connected in series
or parallel to create a wide range of inductance
combinations. The secondary winding could be
used as a feedback winding in switched mode
power supplies.
PIN CONNECTIONS (TOP VIEW)
1
4
2
3
3 & 1 = Primary winding
4 & 2 = Secondary winding


For full details go to
www.murata-ps.com/rohs
www.murata-ps.com
SELECTION GUIDE
Order Code
492R2C
493R3C
494R7C
496R8C
49100C
49150C
49220C
49330C
49470C
49680C
49101C
49151C
49221C
Inductance1
(10kHz, 100mVAC)
1&3, 2&4
Nom.
μH
2.2
3.3
4.7
6.8
10
15
22
33
47
68
100
150
220
Inductance Range
(10kHz, 100mVAC)
1&3, 2&4
Min. - Max.
μH
1.77 - 2.65
2.47 - 3.70
3.29 - 4.93
5.27 - 7.91
7.70 - 11.6
10.6 - 16.0
15.9 - 23.8
24.5 - 36.8
35.1 - 52.6
50.8 - 76.2
73.6 - 110
111 - 166
167 - 251
DC Current2
(parallel connection)
Max.
A
9.50
7.80
6.50
5.40
4.50
3.70
3.00
2.50
2.10
1.71
1.41
1.15
0.95
MECHANICAL DIMENSIONS
DC Resistance
Max.
mΩ
12.6
14.9
17.1
27.0
41.0
53.0
81.0
128
191
233
343
529
805
12.00 (0.472)
2
3
12.00
49100C
XYYWW
(0.472)
1
4
Recommended Footprint Details
1.00
(0.039)
8.00 (0.315) Max.
All dimensions in mm (inches). Package weight: 4g Typ.
5.00
(0.197)
15.00 (0.591)
5.00 (0.197)
ABSOLUTE MAXIMUM RATINGS
Isolation voltage (flash tested for 1 second), pins 3 & 4
Operating free air temperature range
Storage temperature range
500VDC
-40°C to 85°C
-40°C to 125°C
SOLDERING INFORMATION3
Peak reflow temperature
Pin finish
245˚C
Tin
Specifications typical at T = 25°C
A
1 When connecting windings in series, inductance will be 4 times the nominal figure shown.
2 If current is flowing in both windings, the maximum DC current occurs when either the inductance falls to 75% of its nominal value or
when its temperature rise reaches 40°C, whichever is sooner.
3 For further information, please visit www.murata-ps.com/rohs
Technical enquiries - email: mk@murata-ps.com, tel: +44 (0)1908 615232