English
Language : 

KDC_NDTS Datasheet, PDF (1/6 Pages) Murata Manufacturing Co., Ltd. – Isolated 3W Single Output DC/DC Converters
NDTS Series
Isolated 3W Single Output DC/DC Converters
FEATURES
RoHS compliant
Industry standard footprint
Single isolated output
Short circuit protection
Operating temperature range –40°C to
+85°C
Low profile 24 pin case
2:1 Wide input range
5V, 12V, 24V & 48V Input
3.3V, 5V, 12V & 15V Output
Footprint 4.73cm2
UL94V-0 Package materials
No heatsink required
Internal SMD construction
Fully encapsulated
DESCRIPTION
The NDTS series is a range of low profile DC/DC
converters offering a single regulated output over
a 2:1 input voltage range. All parts deliver 3W
output power up to 85°C without heatsinking. A
flyback oscillator design with isolated feedback
is used to give regulation over the full operating
range of 25% to 100% of full load. It is strongly
recommended that external capacitors be used
on input and output to guarantee performance
over full load and input voltage range (see
recommended filter circuit for values).
SELECTION GUIDE
Input
Voltage
Order Code V (Nom.)
NDTS0503C
5
NDTS0505C
5
NDTS0512C
5
NDTS0515C
5
NDTS1203C
12
NDTS1205C
12
NDTS1212C
12
NDTS1215C
12
NDTS2403C
24
NDTS2405C
24
NDTS2412C
24
NDTS2415C
24
NDTS4803C
48
NDTS4805C
48
NDTS4812C
48
NDTS4815C
48
Rated Output
Voltage
V
3.3
5
12
15
3.3
5
12
15
3.3
5
12
15
3.3
5
12
15
Output Current
Min. Load Full Load
mA
mA
227
909
150
600
63
250
50
200
227
909
150
600
63
250
50
200
227
909
150
600
63
250
50
200
227
909
150
600
63
250
50
200
Input
Current
mA
898
806
769
757
350
320
310
310
172
156
149
147
87
83
76
75
Efficiency
(Min.)
%
63
71
76
77
71
73
75
76
71
78
80
84
71
75
80
80
Isolation
Capacitance
pF
28
30
32
33
29
32
35
32
32
32
35
35
32
32
40
40
MTTF2
kHrs
1658
1665
1650
1633
1668
1665
1650
1633
1671
1673
1650
1617
1676
1668
1631
1600
INPUT CHARACTERISTICS
Parameter
Conditions
All NDTS05 types
Voltage range
All NDTS12 types
All NDTS24 types
All NDTS48 types
All NDTS05 types
All NDTS12 types
Reflected ripple current1
All NDTS24 types
All NDTS48 types
Min. Typ. Max. Units
4.5
5
9
9
12
18
V
18
24
36
36
48
72
50
150
30
100
mA p-p
40
50
30
40
OUTPUT CHARACTERISTICS
Parameter
Conditions
Min. Typ.
Voltage set point accuracy With external input/output capacitors
±1
Line regulation
Low line to high line with external input/
output capacitors
0.15
0503, 0505,
1203, 1205
0.8
Load regulation
Minimum load to rated
load with external input/
output capacitors
2403, 2405,
4803, 4805
0.8
12V & 15V
outputs
0.1
Ripple
BW = 20Hz to 300kHz with external input/
output capacitors
15
Ripple & noise
BW = DC to 20MHz with external input/output
capacitors
90
1. Please refer to relected ripple current measurement circuit on page 2.
2. Calculated using MIL-HDBK-217F with nominal input voltage at full load (ground benign) at 25°C.
3. Please refer to minimum load application note on page 4.
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
Max.
±3
0.5
1.0
1.2
0.5
40
150
Units
%
%
%
mV rms
mV p-p
Ḥ
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com
Technical enquiries - email: mk@murata-ps.com, tel: +44 (0)1908 615232
KDC_NDTS_D02 Page 1 of 6