D1U3CS-D-1600-12-HC4EC Datasheet, PDF (1/5 Pages) Murata Manufacturing Co., Ltd. – 81mm Front End DC-DC Power Converter | |||
|
www.murata-ps.com
D1U3CS-D-1600-12-HC4EC Series
81mm Front End DC-DC Power Converter
FEATURES
ï®ï 1600W output power (across the full DC input
voltage range)
ï®ï 1.57"(1U) x 11.0" x 3.2"
ï®ï 93% typical efï¬ciency at 50% FL
ï®ï 12VDC Main output
ï®ï 3.3VSB output (20W)
ï®ï 29W/in3 power density
ï®ï N+1 Redundancy Capable; hot plug/swap
(up to 8 modules in parallel)
ï®ï Active current sharing on 12V main output;
integral MOSFET ORING
ï®ï Over-Voltage, Over-Current; Over-Temperature
Protection
ï®ï Internal variable speed cooling fans
ï®ï PMBus⢠Power Management Bus
ï®ï RoHS Compliant
ï®ï Two-year warranty
www.murata-ps.com/en/3d/acdc.html
www.murata-ps.com/en/3d/acdc.html
www.murata-ps.com/en/3d/acdc.html
www.murata-ps.com/en/3d/acdc.html
www.murata-ps.com/en/3d/acdc.html
www.murata-ps.com/en/3d/acdc.html
Available now at
www.murata-ps.com/en/3d/acdc.html
PRODUCT OVERVIEW
The D1U3CS-D-1600-12-HC4EC is a highly efï¬cient 1600 watt, DC input front end module with a 12V main output and a
choice of 3.3V (20W) standby and airï¬ow direction. The power module is able to current share with up to eight (8) other
power modules of the same type operating in parallel or N+1 redundancy.
The supplies may be hot plugged, and include integral isolation devices.
The power modules are fully protected from overload and overvoltage and are able to auto-recover from
overtemperature faults. A Status LED is provided on the front panel and additional control and status reporting is provided
by hardware logic signals and via a PMBus⢠digital interface.
A low proï¬le sub 1U height enclosure provides an excellent power density of 29W/in3 that is ideal for delivering
reliable, efï¬cient power to servers; workstations; storage systems and other 12V distributed power systems.
ORDERING GUIDE
Model Number
D1U3CS-D-1600-12-HC4EC
Power Output
1600W
Main
Output
12Vdc
Standby
Output
3.3Vdc
Airï¬ow
Back to Front
INPUT CHARACTERISTICS
Parameter
DC Input Voltage Operating Range
Turn-on Input Voltage
Turn-off Input Voltage
Maximum Current @ VIN = -48Vdc
DC Input Inrush Peak Current
Efï¬ciency (-48Vdc)
Reverse polarity protection
Conditions
Min Typ Max Units
-40 -48/-60 -72
Ramp Up
-39.5 -40 -40.5 Vdc
Ramp Down
-35.5 -36 -36.5
1600W
40 Adc
-40
Cold start between 0 to 200ms
-72
50
Apk
100
20% FL
92
50% FL
93
%
100% FL
90
Reversed input cables; no internal
fuse failure
+40
+72 Vdc
OUTPUT VOLTAGE CHARATERISTICS
Output
Voltage
Parameter
Conditions
Min Typ Max Units
Voltage Set Point Accuracy
12
Vdc
Line & Load Regulation
11.4
12.6
Main
Ripple & Noise1
12V
Output Current
20MHz Bandwidth
-40Vdc to -72Vdc DC
Input Voltage Range
0
120 mVPP
133A A
Load Capacitance
30,000 μF
Voltage Set Point
3.3
Vdc
Line & Load Regulation
3.2
3.4
3.3VSB Ripple Voltage & Noise1
20MHz Bandwidth
120 mVPP
Output Current
-40Vdc to -72Vdc
0
6
A
Load Capacitance
10,000 μF
1 Ripple and noise are measurements are to be performed with a parallel combination of a 0.1μF ceramic capacitor and 10μF tantalum
capacitance on each of the power module output measurement nodes. A short coaxial cable from measurement point to âscope shall
be used.
Ḥ
For full details go to
www.murata-ps.com/rohs
CB
Test Certiï¬cate
and Test Report
www.murata-ps.com/support
D1U3CS-D-1600-12-HC4EC.A02 Page 1 of 5
|
▷ |