OKX-T10_1 Datasheet, PDF (5/13 Pages) Murata Power Solutions Inc. – Adjustable DOSA 10/16-Amp SIP DC/DC Converters
PRELIMINARY
OKX T/10 & T/16-W5 Series
Adjustable DOSA 10/16-Amp SIP DC/DC Converters
Performance and Functional Specifications
See Note 1
Input
Input Voltage Range
See Ordering Guide and Note 7.
Start-Up Voltage
2.05V
Undervoltage Shutdown (see Note 15) 1.90V
Overvoltage Shutdown
None
Reflected (Back) Ripple Current (Note 2) 20 mA pk-pk
Internal Input Filter Type
Capacitive
Recommended External Fuse
15A fast blow
Reverse Polarity Protection
N/A. See fuse information
Input Current:
Full Load Conditions
Inrush Transient
Shutdown Mode (Off, UV, OT)
Output in Short Circuit
No Load
Low Line (Vin=Vmin, Vout=Vnom)
See Ordering Guide
0.4 A2Sec.
5 mA
60 mA
80 mA
9.05A (T/10), 14.63A (T/16)
Remote On/Off Control (Note 5)
Negative Logic (“N” model suffix)
Positive Logic (“P” model suffix)
Current
ON = Open pin or ground to +0.4V. max.
OFF =+1.5V min. to + Vin (max)
ON = Open pin (internally pulled up) or
+1.5V to +Vin max.
OFF = Ground pin to +0.4V. max.
1 mA max.
Tracking/Sequencing (OKX “2” models)
Slew Rate
Tracking accuracy, rising input
Tracking accuracy, falling input
2 Volts per millisecond, max.
Vout = ±200 mV max. of Sequence In
Vout = ±400 mV max. of Sequence In
General and Safety
Efficiency
See Ordering Guide
Switching Frequency
300 KHz
Start-Up Time (Vin on to Vout regulated) 8 mSec for Vout=nominal
(On/Off to Vout regulated)
6 mSec for Vout=nominal
Isolation
Not isolated
Safety
Certified to UL/cUL 60950-1,
CSA-C22.2 No. 60950-1, IEC/EN 60950-1
CalculatedMTBFperTelcordiaSR-232(4a) TBC
Calculated MTBF per MIL-HDBK-217F (4b) TBC
Output
Minimum Loading
No minimum load
Accuracy (50% load, untrimmed)
±2 % of Vnominal
Voltage Output Range (Note 13)
See Ordering Guide
Overvoltage Protection (Note 16)
None
Temperature Coefficient
±0.02% per °C of Vout range
Ripple/Noise (20 MHz bandwidth)
See Ordering Guide and note 8
Line/Load Regulation
See Ordering Guide and note 10
Maximum Capacitive Loading (Note 14)
Cap-ESR=0.001 to 0.01 Ohms 1,000 μF
Cap-ESR >0.01 Ohms
5,000 μF (min. cap. load 0 μF)
Current Limit Inception (Note 6)
34 Amps (OKX2-T/16-W5)
(98% of Vout setting, after warm up) 29 Amps (OKX2-T/10-W5)
Short Circuit Mode
Short Circuit Current Output
Protection Method
1A
Hiccup autorecovery upon overload
removal. (Note 7)
Short Circuit Duration
Continuous, no damage
(output shorted to ground)
Prebias Startup
Converter will start up if the external
output voltage is less than Vset
Dynamic Load Response
100 μSec max. to within ±2% of final value
(50-100% load step, di/dt=2.5A/μSec) with 2 x 150 μF polymer external caps.
Environmental
Operating Temperature Range (Ambient)
See derating curves
-40 to +85 deg. C. with derating (Note 9)
Operating PC Board Temperature
-40 to +100 deg. Celsius max.,
no derating (12)
Storage Temperature Range
-55 to +125 deg. C.
Thermal Protection/Shutdown
+130 deg. Celsius
Relative Humidity
to 85%RH/+85 deg. C., non-condensing
Physical
Outline Dimensions
See Mechanical Specifications
Weight
0.2 ounces (5.6 grams)
Restriction of Hazardous Substances
RoHS-6 (does not claim EU RoHS
exemption 7b–lead in solder)
Absolute Maximum Ratings
Input Voltage (Continuous or transient) 0 V.to +5.8 Volts max.
On/Off Control
0 V. min. to +Vin max.
Input Reverse Polarity Protection
See Fuse section
Output Current (Note 7)
Current-limited. Devices can withstand a
sustained short circuit without damage.
The outputs are not intended to accept
appreciable reverse current.
Storage Temperature
-55 to +125 deg. C.
Lead Temperature
See soldering specifications
Absolute maximums are stress ratings. Exposure of devices to greater than any of any
of these conditions may adversely affect long-term reliability. Proper operation under
conditions other than those listed in the Performance/Functional Specifications Table is
not implied nor recommended.
Specification Notes:
(1) Specifications are typical at +25 deg.C, Vin=nominal (+5V.), Vout=nominal (+3.3V), full load, external caps
and natural convection unless otherwise indicated. Extended tests at higher power must supply substantial
forced airflow.
All models are tested and specified with external 1 μF paralleled with 10 μF ceramic output capacitors
and a 22 μF external input capacitor. All capacitors are low ESR types. These capacitors are necessary
to accommodate our test equipment and may not be required to achieve specified performance in your
applications. However, Murata Power Solutions recommends installation of these capacitors. All models are
stable and regulate within spec under no-load conditions.
(2) Input Back Ripple Current is tested and specified over a 5 Hz to 20 MHz bandwidth. Input filtering is
Cin=2 x 100 μF tantalum, Cbus=1000 μF electrolytic, Lbus=1 μH.
(3) Note that Maximum Power Derating curves indicate an average current at nominal input voltage. At higher
temperatures and/or lower airflow, the DC/DC converter will tolerate brief full current outputs if the total
RMS current over time does not exceed the Derating curve.
(4a) Mean Time Before Failure is calculated using the Telcordia (Belcore) SR-332 Method 1, Case 3, ISSUE 2,
ground fixed controlled conditions, Tambient=+25 deg.C, full output load, natural air convection.
(4b) Mean Time Before Failure is calculated using MIL-HDBK-217F, GB ground benign, Tambient=+25 deg.C, full
output load, natural air convection.
(5) The On/Off Control Input should use either a switch or an open collector/open drain transistor referenced to
-Input Common. A logic gate may also be used by applying appropriate external voltages which not exceed
+Vin.
(6) Short circuit shutdown begins when the output voltage degrades approximately 2% from the selected
setting.
(7) “Hiccup” overcurrent operation repeatedly attempts to restart the converter with a brief, full-current output.
If the overcurrent condition still exists, the restart current will be removed and then tried again. This short
current pulse prevents overheating and damaging the converter. Once the fault is removed, the converter
immediately recovers normal operation.
(8) Output noise may be further reduced by adding an external filter. At zero output current, the output may
contain low frequency components which exceed the ripple specification. The output may be operated
indefinitely with no load.