7.2 ON/OFF control
ON/OFF function
The DC-DC Converter can be inactive by using ON/OFF function.
MYSSM01204BENL DATA Sheet
5
ON/OFF control method
When ON/OFF-pin(9pin) is connected to Vin
・・・ Output Voltage=OFF
When ON/OFF-pin(9pin) is connected to GND or Open ・・・ Output Voltage=ON
Usage example
Vin pin
MYSSM01204BENL
R1
or
ON/OFF pin
24kΩ
22kΩ
※ R1=10kΩ ~ 100kΩ
8. Reliability
8.1 Humidity
According to JIS-C-0022.
40 土2°C, 90 to 95%RH, 100 hours. Leave for 4 hours at room temperature.
No damage in appearance and no deviation from electrical characteristics (section 6.1.).
8.2 Temperature Cycles
Repeat cycle 5 times. Leave 2 hours at room temp.
No damage in appearance and no deviation from electrical characteristics (section 6.1.).
Step
1
2
3
4
Condition
-40°C±3°C
Room Temp.
+85°C±2°C
Room Temp.
Time
30 minutes
5-10 minutes
30 minutes
5-10 minutes
8.3 Vibration
10 to 55Hz, 1.5mm amplitude (1minute cycle), 1 hour for each of X, Y, Z directions.
No damage in appearance and no deviation from electrical characteristics (section 6.1.).
8.4 Mechanical Shock
20G, 1 time for each X, Y, Z directions.
No damage in appearance and no deviation from electrical characteristics (section 6.1.).
Note:
1. This datasheet is downloaded from the website of Murata Manufacturing co., ltd. Therefore, it’ s specifications are subject to change or our
products in it may be discontinued without advance notice. Please check with our sales representatives or product engineers b efore ordering.
2. This datasheet has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product
specifications or transact the approval sheet for product specifications before ordering.
2014.2.8