FUNCTIONAL SPECIFICATIONS, (CONT.)
OUTPUT
Total Output Power
Voltage
Nominal Output Voltage
Output Voltage
Setting Accuracy
Overvoltage Protection
Current
Output Current Range
Cold condition
After warm up
Short Circuit
Short Circuit Current
Short Circuit Duration
(remove short for recovery)
Short circuit protection method
Regulation ➄
Line Regulation
Load Regulation
Ripple and Noise ➅
Temperature Coefficient
Maximum Capacitive Loading
MECHANICAL (Through Hole Models)
Outline Dimensions (with heat sink)
(Please refer to outline drawing)
Outline Dimensions (with baseplate)
Conditions ➀
No trim (@ all conditions)
@ Vin=48V, Iout=0, temp=+25°C
At 50% load, no trim
Via magnetic feedback
Default, Configurable via PMBUS
Default, Configurable via PMBUS
Hiccup technique, autorecovery within ±1.25%
of Vout
Output shorted to ground, no damage
Current limiting
Vin = 38 to 75V, Vout = nom., Iout = nom.
Iout = min. to max., Vin = 48V
5 Hz- 20 MHz BW
At all outputs
Low ESR
LxWxH
Through Hole Pin Diameter
Through Hole Pin Material
TH Pin Plating Metal and Thickness
ENVIRONMENTAL
Operating Ambient Temperature Range
Operating Case Temperature
Storage Temperature
Thermal Protection/Shutdown
Electromagnetic Interference
Conducted, EN55022/CISPR22
RoHS rating
Nickel subplate
Gold overplate
See Derating
No derating
Vin = Zero (no power)
Measured in center
External filter is required
DRQ-12/42-D48 Series
500W Digital Fully Regulated
Intermediate DC-DC Bus Converter
Minimum
0
11.16
11.45
-2
13.8
0
52
51
Typical/Nominal
500.25
11.5
14.4
54
53
0.4
Continuous
Maximum
515.5
11.85
11.55
2
15.6
43.5
56
55
1
Units
W
Vdc
Vdc
% of Vnom
Vdc
A
A
A
30
100
mV
50
100
mV
80
120
mV pk-pk
0.01
0.02
% of Vout./°C
10000
μF
2.3 x 1.45 x 1.1
58.4 x 36.83 x 27.94
2.3 x 1.45 x 0.52
58.4 x 36.8 x 13.21
0.04 & 0.062
1.016 & 1.575
Copper alloy
98.4-299
4.7-19.6
Inches
mm
Inches
mm
μ-inches
μ-inches
-40
85
°C
-40
110
°C
-55
125
°C
132
°C
B
Class
RoHS-6
Notes
➀ Unless otherwise noted, all specifications apply at Vin = nominal, nominal output voltage and full
output load. General conditions are near sea level altitude, no base plate installed and natural
convection airflow unless otherwise specified. All models are tested and specified with external
parallel 1 μF and 10 μF output capacitors (see Technical Notes). All capacitors are low-ESR types
wired close to the converter. These capacitors are necessary for our test equipment and may not
be needed in the user’s application.
➁ Input (back) ripple current is tested and specified over 5 Hz to 20 MHz bandwidth. Input filtering is
Cin = 33 μF/100V, Cbus = 220μF/100V and Lbus = 12 μH.
➂ All models are stable and regulate to specification under no load.
➃ The Remote On/Off Control is referred to -Vin.
➄ Regulation specifications describe the output voltage changes as the line voltage or load current
is varied from its nominal or midpoint value to either extreme. The load step is ±25% of full load
current.
➅ Output Ripple and Noise is measured with Cout = 1 μF || 10 μF, 20 MHz oscilloscope bandwidth
and full resistive load.
www.murata-ps.com/support
MDC_DRQ-12/42-D48.A03 Page 4 of 24