MVAC400-24AFT Datasheet, PDF (3/8 Pages) Murata Power Solutions Inc. – 400W 3 x 5 High Density AC-DC Power Supply Converter
MVAC400 Series
400W 3" x 5" High Density AC-DC Power Supply Converter
EMISSIONS AND IMMUNITY
Characteristic
Input Current Harmonics
Voltage Fluctuation and Flicker
Conducted Emissions
ESD Immunity
Radiated Field Immunity
Electrical Fast Transient Immunity
Surge Immunity
Radiated Field Conducted Immunity
Magnetic Field Immunity
Voltage dips, interruptions
Standard
IEC/EN 61000-3-2
IEC/EN 61000-3-3
EN 55022
FCC Part 15
IEC/EN 61000-4-2
IEC/EN 61000-4-3
IEC/EN 61000-4-4
IEC/EN 61000-4-5
IEC/EN 61000-4-6
IEC/EN 61000-4-8
IEC/EN 61000-4-11
Compliance
Class A
Complies
Class B
Class B
Level 4, Criterion 2
Level 3, Criterion A
Level 4, Criterion A
Level 3, Criterion A
Level 3, 10V/m, Criterion A
Level 3, Criterion A
Level 3, Criterion B
EMI CONSIDERATIONS
For optimum EMI performance, the power supply should be mounted to a metal plate grounded to all 4 mounting holes of the power supply. To comply with safety standards, this
plate must be properly grounded to protective earth (see mechanical dimension notes). Pre-compliance testing has shown the stand-alone power supply to comply with EN55022
class A radiated emissions. Class B radiated emissions are achievable with a metal enclosure. Radiated emission results vary with system enclosure and cable routing paths.
SAFETY CONSIDERATIONS
1. This power supply is a component level power supply intended for use in Class I or Class II applications. Secondary ground traces need to be suitably isolated
from primary ground traces when used in Class II applications.
2. When the power supply is used in Class II equipment, all ground traces and components connected to the primary side are considered primary for spacing and
insulation considerations.
STATUS AND CONTROL SIGNALS
Parameter Models
Conditions
PS_ON
MVAC400-xxAF
MVAC400-xxAFD
MVAC400-xxAFR
This pin must be pulled low (sink current >2mA) to +5V_AUX_RTN to turn on the main and Fan (V2) output. The +5V_AUX output is independent of
the PS_ON signal, and comes up automatically when the input AC or input DC voltage is applied within their specified operating ranges.
MVAC400-xxAFT
This pin is pulled high internally and so all three outputs (main, Fan output and +5V_AUX) come up automatically when the input AC or input DC voltage
is applied within their specified operating ranges. Pulling this pin low (sink current >2mA) to +5V_AUX_RTN will disable the main and fan outputs.
PWR_OK All Models
Open collector logic goes high 50-200ms after the main output is within regulation; it goes low at least 6msecs before loss of regulation. Internal
10K pull up to +5V_Aux is provided. Applications using the PWR_OK signal should maintain a minimum load of 5W on the main or fan output.
1. Noise and ripple is measured at an oscilloscope jack on the output, 20MHz bandwidth, and with
0.1µF ceramic and 10µF aluminum electrolytic capacitors across the output pins.
2. Unless otherwise specified all measurements are taken at 120Vac input and 25°C ambient
temperature.
3. Fan (V2) regulation band applies from 0.1A to 1A load with a minimum of 10W load on the main
(V1) output.
4. Fan (V2) has overvoltage protection (tracking V1) and short circuit protection. Overloading the Fan
(V2) output can result in permanent damage to the unit.
5. 24V and 50V models may exhibit up to 5% turn on overshoot for loads less than 4% of full load.
PART NUMBER STRUCTURE
6. Load regulation for droop version models (MVAC400-xxAFD and MVAC400-xxAFR) is based the
calculated droop voltage ±1.5% (see current sharing section for droop characteristics).
7. No load Input power varies by model and by input line. Measurement is difficult to make due to burst
mode operation. Please contact Murata sales if additional information is required.
8. All three output returns are isolated from each other (see isolation characteristics section); the
returns may be tied together externally.
9. Load steps beginning from combined loads on the main and fan outputs of less than 5W may
result in transient undershoots outside of the spec limits.
10. For MVAC400-xxAFR models only: Measured with 220µF capacitance across main output.
MV A x yyy - zz hhh
Murata Manufacturing Corp.
Form Factor Outline
A = 2x4", 3x5", or 4x7"
Modification Code Options
A = Aux 5V Standby Voltage
F = Aux 12V Fan Output
D = Droop Current Share
T = Terminal Output Connector
R = Terminal Output Connector with Internal Or-ing Solution and Droop Current Share
Outline Detail
B & D = 2x4"
C = 3x5"
F = 4x7"
Main Output Voltage (V)
(12, 24, 28, or 48)
Output Power (W)
(40, 65, 120, 160, 250, 400, or 750)
www.murata-ps.com/support
MVAC400.B02 Page 3 of 8