English
Language : 

OKX-T5-D12 Datasheet, PDF (2/15 Pages) Murata Power Solutions Inc. – Adjustable 5-Amp SIP Non-Isolated DC/DC Converters
OKX-T/5-D12 Series
Adjustable 5-Amp SIP Non-Isolated DC/DC Converters
PERFORMANCE SPECIFICATIONS SUMMARY AND ORDERING GUIDE
Output
VOUT
Model Number ➀ (Volts) ➀
IOUT
R/N
(Amps, Power (mVp-p)
max) ➀ (Watts) Max. d
Regulation (Max.)
Line
Load
OKX-T/5-D12-C .7525-5.5 5
25
25 ±0.2% ±0.5%
Input
Iin,
Vin Nom. Range no load
(Volts) (Volts) e (mA)
12 8.3-13.8 45
Iin,
full load
(Amps)
Efficiency
Min. Typ.
2.24 91.5% 93.0%
Case
Dimensions are
in inches (mm)
0.40x0.90x0.282
(10.16x 22.86x 7.163)
➀ All specifications are at nominal line voltage, Vout=nominal (5V for D12 models) and full load, +25°C unless otherwise
noted.
d Ripple and Noise (R/N) is shown at Vout=1V. See specs for details.
e The input voltage range must be 0.5V greater than the output voltage.
PART NUMBER STRUCTURE
OK X - T / 5 -D12 N - C
Okami Non-isolated PoL
RoHS Hazardous Substance Compliance
C = RoHS-6 (does not claim EU RoHS
exemption 7b–lead in solder)
SIP Mount
Trimmable Output
Voltage Range
D12 Models = 0.7525-5.5V
On/Off Logic
P = Positive Logic
N = Negative Logic
Maximum Rated Output
Current in Amps
Input Voltage Range
D12 = 8.3-13.8V
Note: Some model number combinations
may not be available. See Ordering Guide
above. Contact Murata Power Solutions for
availability.
www.murata-ps.com/support
MDC_OKX-T/5-D12 Series.A01 Page 2 of 15