ENVIRONMENTAL CHARACTERISTICS
Parameter
Storage Temperature Range
Operating Temperature Range
Operating Humidity
Operating Altitude
MTBF
Shock
Vibration
Safety
Warranty
Outside Dimensions
Weight
PROTECTION CHARACTERISTICS
Parameter
Overvoltage Protection
Overcurrent Protection
Overtemperature Protection
ISOLATION CHARACTERISTICS
Parameter
Isolation
Leakage Current (under normal conditions)
Touch Current
EMISSIONS AND IMMUNITY
Characteristic
Input Current Harmonics
Voltage Fluctuation and Flicker
Conducted Emissions
ESD Immunity
Radiated Field Immunity
Electrical Fast Transient Immunity
Surge Immunity
RF Conducted Immunity
Magnetic Field Immunity
Voltage dips, interruptions
6 At Ta<50°C.
7 Class I equipment deployment.
hptotwp:e/r/.pmouwreart.am.cuormata.com
MVAD160 Series
160W 2" X 4" AC-DC Power Supply Converter
Conditions
Min.
Typ.
Max.
-40
85
Refer to power derating curve vs. operating temperature
-40
85
Start up
-40
Non-condensing
10
95
For class I IT equipment deployment
-200
5000
Other
-200
2000
Telcordia SR-332 M1C3 50°C, 110W
1M
Operating, IEC60068-2-27, half-sine 5G, 6ms, 3 times
per face, 6 faces
Complies
Non-operating, IEC60068-2-27, half-sine, 30G, 18ms, 3
times per face, 6 faces
Complies
Operating, IEC60068-2-6, 1.0G, 10-150Hz, 10minutes
per axis, on all 3 axes
Complies
Non-operating, IEC60068-2-6, 2.0G, 10-150Hz, 10min-
utes per axis, on all 3 axes
Complies
IEC60950-1:2005 2nd Ed.; Am1:2009
EN60950-1:2006; A11:2009; A1:2010; A12:2011
UL60950-1, 2nd Ed., 2011-12-19 & CSA C22.2 No. 60950-1-07, 2nd Ed., 2011-12
IEC60601-1:2005 3rd Ed. + CORR.1(2006) + CORR.2(2007)
ANSI/AAMI ES60601-1 (2005+C1:09 + A2:10), CSA-C22.2 No. 60601-1(2008), MOPP
CE Marking per LVD
2 years6
2.0" x 4.0" x 1.5" (50.8mm x 101.6mm x 38.1mm)
0.42lbs (190g) typical
Units
°C
%
m
Hours
Conditions
V1; Latching (50% load)
V2; Latching (50% load)
V1; Hiccup mode; Auto Recovery
V2; Hiccup mode; Auto Recovery
Auto recovery
Min.
Typ.
Max.
Units
110
140
110
170
%
110
170
0.11
0.4
A
Complies
Conditions
Primary to Earth Ground (1x MOPP)
Primary to Secondary (2x MOPP)7
Secondary to Earth Ground
264Vac, 60Hz, 25°C
240Vac, 60Hz, 25°C
264Vac, 60Hz, 25°C
Min.
Typ.
Max.
Units
1500
Vac
4000
500
Vdc
350
μA
300
μA
100
μA
Standard
IEC/EN 61000-3-2
IEC/EN 61000-3-3
EN 55022
FCC Part 15
IEC/EN 61000-4-2
IEC/EN 61000-4-3
IEC/EN 61000-4-4
IEC/EN 61000-4-5
IEC/EN 61000-4-6
IEC/EN 61000-4-8
IEC/EN 61000-4-11
Compliance
Class D, Class C
Complies
Class B, (Class A as Class II equipment deployment)
Class B, (Class A as Class II equipment deployment)
Level 4, Criterion A
Level 2, Criterion A
Level 3, Criterion A
Level 4, Criterion A
Level 2, Criterion A
Level 2, Criterion A
Level 3, Criterion B
MVAD160.A05 Page 2 of 6