English
Language : 

MVAD065-12 Datasheet, PDF (2/7 Pages) Murata Power Solutions Inc. – 65W 2 x 4 AC-DC Power Supply Converter
ENVIRONMENTAL CHARACTERISTICS
Parameter
Storage Temperature Range
Operating Temperature Range
Operating Humidity
Operating Altitude
MTBF
Shock
Vibration
Safety
Warranty
Outside Dimensions
Weight
PROTECTION CHARACTERISTICS
Parameter
Overvoltage Protection
MVAD065-05
Other
Overcurrent Protection
ISOLATION CHARACTERISTICS
Parameter
Isolation
Leakage Current (under normal conditions)
Touch Current
EMISSIONS AND IMMUNITY
Characteristic
Input Current Harmonics
Voltage Fluctuation and Flicker
Conducted Emissions
ESD Immunity
Radiated Field Immunity
Electrical Fast Transient Immunity
Surge Immunity
RF Conducted Immunity
Magnetic Field Immunity
Voltage dips, interruptions
4. At class I equipment.
power.murata.com
MVAD065 Series
65W 2" x 4" AC-DC Power Supply Converter
Conditions
Min.
Typ.
Max.
-40
85
See thermal derating curves
-10
70
Start up
-20
Non-condensing
10
95
For Class I ITE Equipment deployment
-200
5000
Other
-200
2000
Telcordia SR-332 M1C3 25°C
1M
Operating, IEC60068-2-27, half-sine 5G, 6ms,
3 times per face, 6 faces
Complies
Non-operating, IEC60068-2-27, half-sine,
30G, 18ms, 3 times per face, 6 faces
Complies
Operating, IEC60068-2-6, 1.0G, 10-150Hz, 10
minutes per axis, on all 3 axes
Complies
Non-operating, IEC60068-2-6, 2.0G,
10-150Hz, 10 minutes per axis, on all 3 axes
Complies
IEC60950-1:2005 (2nd Edition); Am1:2009
UL60950-1 2nd Edition,2011-12-19, CSA C22.2 No. 60950-1-07, 2nd Edition,2011-12
EN60950-1:2006 + A11:2009 + A1:2010 + A12:2011
IEC60601-1:2005 + CORR.1(2006) + CORR.2(2007)
ANSI/AAMI ES60601-1 (2005+C1:09 + A2:10), CSA-C22.2 No. 60601-1(2008), MOPP
CE Marking per LVD
2 years
2.0" x 4.0" x 1.3" (50.8mm x 101.6mm x 33.02mm)
MVAD065-05 / MVAD065-18
Other
0.285lbs (130g) typical
0.27lbs (123g) typical
Units
°C
%
m
Hours
Conditions
Latching (50% load)
Latching (60% load)
Hiccup mode
Min.
Typ.
Max.
Units
110
110
190
160
%V1
110
160
%A
Conditions
Primary to Earth Ground (1xMOPP)
Primary to Secondary (2xMOPP)4
Secondary to Earth Ground
240Vac, 60Hz, 25°C
264Vac, 60Hz, 25°C
264Vac, 60Hz, 25°C
Min.
Typ.
Max.
Units
1500
Vac
4000
500
Vdc
300
350
µA
100
Standard
IEC/EN 61000-3-2
IEC/EN 61000-3-3
EN 55022
FCC Part 15
IEC/EN 61000-4-2
IEC/EN 61000-4-3
IEC/EN 61000-4-4
IEC/EN 61000-4-5
IEC/EN 61000-4-6
IEC/EN 61000-4-8
IEC/EN 61000-4-11
Compliance
Class A
Complies
Class B, Class A (at Class II equipment)
Class B, Class A (at Class II equipment)
Level 4, Criterion A
Level 2, Criterion A
Level 3, Criterion A
Level 4, Criterion A
Level 2, Criterion A
Level 2, Criterion A
Level 3, Criterion B
MVAD065.B01  Page 2 of 7