ENVIRONMENTAL CHARACTERISTICS
Parameter
Storage Temperature Range
Operating Temperature Range
Operating Humidity
Operating Altitude
MTBF
Shock
Operational Vibration
Safety – Medical Standards
2 x MOPP (Primary-Secondary)
Safety – ITE Standards
Warranty
Outside Dimensions
Weight (typ.)
Conditions
Min.
Typ.
Max.
-40
85
See power rating curves
-10
70
Start up
-20
Non-condensing
10
95
-200
5000
Telcordia SR-332 M1C3 @25°C
474K
Operating, MIL-HBK-810E
Complies
Non-operating, MIL-HBK-810E
Complies
IEC-68-2-27 standard
Complies to levels of IEC721-3-2
IEC60601-1 (Ed. 3) – CB Cert and Report
ANSI/AAMI ES60601-1 (2005+C1:09+A2:10)
CAN/CSA 22.2 No. 60601-1 (2008) 3rd Edition
EN60601-1:2006+CORR:2010
UL60950-1, 2nd Edition, 2011-12-19
CSA22.2 No.60950-1-07, 2nd Edition, 2001-12.
EN60950-1:2006+A11:2009/A1/2010/A12:2011
IEC 60950 (ed.2), IEC60950 (ed.2); am1
CE Marking per LVD
2 years
3.0" x 5.0" x 1.4" (76.2mm x 127mm x 35.6mm)
0.8lbs (362.87g)
Units
°C
%
m
Hours
RESIDUAL RISK (PER ISO 14971 & IEC60601-1) FOR USER CONSIDERATION
Fault Condition
Residual Risk
Complies
Contact your Murata salesperson for details
PROTECTION CHARACTERISTICS
Parameter
Over Voltage Protection4
Over Current Protection4
Over Temperature Protection
Remote Sense Short Circuit Protection
Remote Sense Reverse Connection Protection
Conditions
V1 (main output) latching
V3 (aux output) latching
V1, hiccup mode
V3, auto-recovery
Auto-recovery
Min.
Typ.
Max.
110
125
5.5
7.5
110
130
110
150
Complies
Complies
Complies
Units
%
V
%Amax
ISOLATION CHARACTERISTICS
Parameter
Isolation
Earth Leakage Current (under single fault condition)
Earth Leakage Current (under normal conditions)
Conditions
Primary to Chassis
Primary to Secondary (2xMOPP)
Secondary to Chassis
Output to Output
264Vac, 60Hz, 25°C
264Vac, 60Hz, 25°C
Min.
Typ.
Max.
Units
1500
4000
Vac
500
500
300
µA
150
µA
CURRENT SHARING OPTION – MVAC400-xxAFD AND MVAC400-xxAFR
Model Number
Description
MVAC400-12AFD
MVAC400-24AFD
MVAC400-48AFD
MVAC400-12AFR
Main Output: Current share is achieved using the droop method. Nominal output voltage is achieved at 50% load and output voltage increases/drops at a rate of:
• 30mv per amp for the 12V output
• 120mV per amp for the 24V output
• 500mV per amp for the 50V output.
Startup of parallel power supplies is not internally synchronized. If more than 400W combined power is needed, start-up synchronization must be provided by
using a common PS_ON signal. To account for ±10% full load current sharing accuracy and the reduction in full load output voltage due to droop, available
output power must be derated by 15% when units are operated in parallel. Current sharing can be achieved with or without remote sense connected to the
common load.
If ORing protection is desired, use the AFR model or if the AFD model is selected please contact Murata sales for external ORing FET board or external ORing
FET reference circuit design (also see Applications Note ACAN-42).
Aux (V3) output can be tied together for redundancy but total combined output power must not exceed 10W, external ORing devices must be used.
Fan (V2) can be tied together for redundancy but total com load must not exceed 12W, external ORing devices must be used.
www.murata-ps.com/support
MVAC400.B02 Page 2 of 8