English
Language : 

MVAC-COVER Datasheet, PDF (2/2 Pages) Murata Power Solutions Inc. – Enclosure Assembly for MVACxxx Series
MECHANICAL DIMENSIONS
MVAC-COVER
Enclosure Assembly for MVACxxx Series
21.0
95.0
WINDOW FOR
ACCESSING
INPUT CONNECTOR
& GROUND TERMINAL
137.0
WINDOW FOR
ACCESSING
OUTPUT
CONNECTORS
21.0
95.0
15.0
107.0
23.5
90.0
SAFETY CONSIDERATIONS
1. Refer to the relevant MVAC datasheet of the product to be deployed in the MVAC-COVER assembly.
2. A protective bonding conductor from the end product protective earthing terminal must be tied to TB1.
3. This enclosure can only be used with a Class I deployment and is not suitable for Class II deployment.
4. Ensure that the insulator is correctly aligned and fits correctly and is flush with the chassis base.
5. The chassis standoffs are dimensioned to provide the correct clearance in conjunction with the insulator.
6. Do not operate the power supply with the cover removed. The primary heatsink is considered a live primary circuit, and should not be touched.
7. It is the responsibility of the end user to ensure that in all cases, the applicable safety standards are applied to provide the proper creepage and clearance requirements,
and to comply with the safety certification requirements of the installed MVAC product.
8. Used only in non-tropical conditions.
9. There are a total of 10 M3 inserts for mounting the enclosure:
6 on the bottom of the chassis (maximum screw penetration of 3mm)
4 on the side walls maximum screw penetration of 5mm)
10. This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to:
http://www.murata-ps.com/requirements/
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
This product is subject to the following operating require-
ments and the Life and Safety Critical Application Sales
Policy. Refer to: http://www.murata-ps.com/requirements/
Murata Power Solutions, Inc. (“Murata”) makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the
granting of licenses to make, use, or sell equipment constructed in accordance therewith. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards that anticipate dangerous consequences of failures, monitor failures and their consequences, lessen
the likelihood of failures that might cause harm, and take appropriate remedial actions. Buyer will fully indemnify Murata, its affiliated companies, and its representatives against any damages arising out of the use of any Murata products in safety-critical applications. Specifications are subject
to change without notice.
© 2014 Murata Power Solutions, Inc.
www.murata-ps.com/support